background image

 

 Pulsports-100/200   

 Pulsports-100/200

 

E12-    -E13

 

 

11. 

Ft.los mode (Just For Opal/Ruby 200 Only)   

1. Calculates the weight of fat lost during exercise. 

  FT.LOS

 

2. The actual weight of fat lost from exercise can be important, and it 

is a valuable reference of weight loss. 

3. The range of fat loss is from 0 to 9999.99 g. 

12

. Maximum mode 

 

 

 

1. Monitors and records the maximum heart rate during exercise. 

            MAX 

2. The range of maximum heart rate is from 40 to 240 bpm. 

13.

 In target zone time mode

1. Calculates and records the exercise time within the target zone. 

     

 

           IN.TM

 

2. The range is from 00H00M00S to 99H59M59S.

 

14. 

Above target zone mode 

 

 

1. Calculates and records the exercise time NOT in the target zone. 

         OVR.TM

 

2. The range is from 00H00M00S to 99H59M59S.

 

15. 

User date mode (Just For Opal/Ruby 200 Only)

1. Enters the data for sexuality, age, weight and height of user. 

          USER

 

2. Personal data is an important reference for calculating the 

consumption of calories. 

3. Range of age from 5 to 99. 

4. 

Unit of weight: kg from 10 to 199

 

                 

lb from 10 to 499

 

6. 

a). Press P.MODE to select “

USER

” mode. 

User data setting:

 

b). Press SET for 2 seconds to enter user date setting mode. 

c). Press P.MODE to change setting mode. 

d). Press T.MODE or ST/SP to change Sexuality: male or female. 

e). Press T.MODE or ST/SP to change Weight Unit: kg or lb. 

f). Refer the 

Data Setting Processes

Fig. E) USER DATA SETTING

 

  to adjust the User data. 

(Refer Fig .E)

 

   
16. 

Average mode 

 

 

1. Calculating the average heart rate during exercise. According to 

this value we can know if the cardiopulmonary condition has 

been improved while do the same intensity of exercise. 

    

            AVG

 

2. Range of average from 40 bpm to 240 bpm. 

 

 

precautions 

1. Take care of you chest belt. Wash the chest belt by suds, then flush 

out with water. Let it dry it naturally, avoiding putting the chest belt 
under the environment of high temperature or touching the corrosive 

as strong acid or alkalis material. 

2. Wetting the skin, where will contact the conductive area of the chest 

belt will improve the conduction and get more stable signal. 

3.

 

The physical condition of individual might effect the intensity of 

measured signal. 

4. Avoiding using the heart rate monitor close to trolley car, tram stop, 

transformer, electric substation and high-tension distribution line etc.   
Because the radio signal will be affected under the environment as 
high voltage and strong magnetic field. 

5. Although the water resist of this watch has been approved as 30 

meter, but please do not operate any button of the watch under 
water. This watch is not designed for diving. 

6. Battery can be used for 1 year according to daily use for 2 hours.  

Please change the battery by watch shop, and do not break the 
watch down by your own. 

SPECIFICATIONS 

OPAL/RUBY 100/200 Pulse Transmitter: 

 Battery type: CR2032 

 Battery life: Average 1300 hours. 

           (You can change the battery by yourself.) 

 Operating temperature: -10

°

C~50

°

C (14

°

F~122

°

F) 

OPAL/RUBY100/200 Pulse Wrist Receiver: 

 Battery type: CR2025 

 Battery life: About 1 year. 

 Operating temperature: -10

°

C~50

°

C (14

°

F~122

°

F) 

 Water resistance: 3 ATM

 

 

Summary of Contents for Opal-100

Page 1: ... Start Stop Heart Rate Data Record Function 9 Reset Heart Rate Record Data 10 Heart Rate Display Description 10 Target Zone Limit 10 Stop Watch Mode 11 Calories Mode 11 Exercise Time Mode 11 Weight Lose Mode 11 Fat Loss Mode 11 Ft los Mode 12 Maximum Mode 12 In Target Zone Time Mode 12 Above Target Zone Mode 12 User Data Mode 12 Average Mode 12 11 PRECAUTIONS 13 12 SPECIFICATIONS 13 13 USER GUIDE ...

Page 2: ...sen the stretch band Fig 1 2 and 3 2 Adjust the length of the stretch band until you feel conformable but the stretch band must cling to the chest then fasten the fastener at the other end Fig 4 3 Adjust the sensor to the center of your chest and be sure the backside of the sensor is clings to your chest and touches the skin Fig 5 6 4 The chest belt has to be worn while using the heart rate functi...

Page 3: ...etting T MODE Press to add one unit to the value Hold to increase the value automatically P MODE Press to change the value ST SP Press to decrease the value Hold to decrease the value automatically Fig A TIME MODE CIRCULATION Fig B PULSE MODE CIRCULATION Fig C DATA SETTING PROCESSES 1 Press P MODE to change setting digit 2 Press T MODE to add to the value hold to add to the value automatically 3 P...

Page 4: ...rom exercise 0 to 9999 99g according to your personal data input Just For Opal Ruby 200 Only 8 MAX Maximum HR during exercise 40 to 240 bpm 9 IN TM Exercise time within setup target zone 00 00 00 to 99 59 59 10 OVR TM Time over upper limit of target zone during exercise 00 00 00 to 99 59 59 11 USER User data setup age 5 to 99 weight 10 to 199 kg or 10 to 499lbs and sex Just For Opal Ruby 200 Only ...

Page 5: ...o 2099 Date mode 2 Day of week will display automatically while the date is input 3 a Press T MODE to select DATE mode Date setting b Press SET for 2 seconds to enter data setting mode c Refer the Data Setting Processes to adjust the Date data 1 Press ST SP to start stop chronometer Chronometer mode 2 Press T MODE for 2 seconds to reset chronometer data 3 Maximum range is 99H59M59S HEART RATE FUNC...

Page 6: ...tes the calories expended for the whole exercise process not only from exercise CAL 2 Males expend more calories than females at the same heart rate likewise the female heart rate will be higher than male heart rate doing the same amount of exercise 3 Calories consumption will be affected by Heart rate sexuality weight and type of exercise 4 The unit of calories is Kcal 5 The range is from 0 Kcal ...

Page 7: ...ing the average heart rate during exercise According to this value we can know if the cardiopulmonary condition has been improved while do the same intensity of exercise AVG 2 Range of average from 40 bpm to 240 bpm precautions 1 Take care of you chest belt Wash the chest belt by suds then flush out with water Let it dry it naturally avoiding putting the chest belt under the environment of high te...

Page 8: ...and fat can provide energy to body by burning oxygen Normally 5 Kcal will be used for 1 liter of oxygen The burning oxygen and generated energy is proportional Correlation of Basic Metabolism and Heart Rate So when the body needs more oxygen to burn the frequency of breath and heart beat will increase to provide more oxygen Basic energy requirement ETotal basic metabolism energy consumption Formul...

Page 9: ...ecause of an increase in vital capacity transport more blood and oxygen are transported by each contraction of the heart and the skeletal muscles also receive more oxygen This can be monitored if you use Pulsports as a guide for exercise You can also find that recovery time will decrease as the cardiopulmonary condition is improved According to the statistics on cardiopathy in people with differen...

Page 10: ... references regarding the intensity of exercise there are the following levels HR_Intensity 35 Very light 35 54 Light 55 69 Moderate 70 89 Hard 90 Very hard 100 Maximal d You can know your heart rate heart rate intensity and calories consumption per hour while exercising by the Pulsport monitor 2 3 According to the purposes of exercise here are example of duration and frequency Duration and Freque...

Page 11: ...opping 0 5 hr 80 Kcal 60 Kcal You can calculate how many Kcal you need for daily work from the above table 2 Ideal body weight We know that there are many different equations for calculating the ideal body weight and usually we use the ACSM equation which uses BMI Body Mass Index as a reference for ideal body weight BMI Weight kg square of height m2 Ideal BMI value for males is 22 Ideal BMI value ...

Page 12: ...form of exercise deducting 20 water related to fat Pulsports will display the actual weight of fat lost f CAL H Calories expenditure per hour Increasing or decreasing the intensity of heart rate can control target calories consumption For instance a 25 years old female with a weight of 50 kg exercising at the level of light intensity Calories expenditure per hour 210 Kcal 4 2 50 255 Kcal 5 1 50 Ma...

Page 13: ...down after exercise can help you avoid athletic injuries The correct exercise process requires at least 5 10 minutes warm up Each target zone shift also requires 3 5 minutes to become stable The target zone alarm will be in effect during this period do not worry about it so much The body is adjusting to the intensity of heart rate so do not let the beep affect your current exercise tempo Otherwise...