Power Connections
Use the 2 way terminal connector provided to
connect the unit to the ships supply. Ensure the
connector is wired as indicated in Fig. 3.
Note: If the alarm is active on Box 2 the Green LED indicator
on Box 1 will show an extended flash whenever a radar pulse is
detected. For correct indication, it is suggested to use the alarm
on Box 1 only.
When using an external alarm, the alarm should be wired to
Box 1, as shown in Figure 7.
Using Dual Control Boxes with Active-X & X-S RTE
The standard control box may be dual stationed to an exterior
waterproof one as shown below.
0V
+12V
PWR
SHIPS SUPPLY
0V
+12V
Cutting Template
RTE Connections
Use the 3 way terminal connector provided
to connect the unit to the active X-S antenna.
Ensure the connector is wired as indicated in
Fig. 4. If an X Band RTE is being wired just
connect the blue and brown wires.
External Alarm Connections
The unit has the ability to supply a switched signal for an external
alarm. This alarm will operate along with the internal audible alarm.
Use the 4 way terminal connector, provided, to connect the unit to
the external alarm. Ensure the connector is wired as indicated in Fig. 5.
The “EXT ALARM” connections are a switched relay.
The user must provide an external signal to be switched through
these relay connections.
To enable the external alarm the “EXT ALARM ENABLE”
connections must be linked together. It is suggested that this link
is made through a toggle switch to provide a means of disabling
the external alarm.
Note: disabling the internal audible alarm WILL NOT affect the ex-
ternal alarm.
Fig. 5:
External alarm
connectivity
Fig. 6: Dual station connection
Fig. 4: RTE connectivity
0V +12V SNS
RTE
TO ACTIVE
X-S ANTENNA
BLUE
BROWN
GREEN
+
YELLOW
EXT
ALARM
EXT
ALARM
ENABLE
EXTERNAL ALARM
SWITCHED CONTACTS
FOR EXTERNAL ALARM
CONNECT THE ENABLE
TERMINALS TOGETHER
INCLUDE A SWITCH IN
CIRCUIT TO GIVE TOGGLE
CONTROL OF THE EXTERNAL
ALARM FACILITY
2
Fig. 3: Power supply
Manufactured by
Echomax Products in the UK
PO Box 6032, Dunmow CM6 3AS, UK.
Email: [email protected] www.echomax.co.uk
Tel: 00 44 (0) 1371 830216 Fax: 831733
HO
LE
SA
W
ÿ 57
mm
(21
/ 4"
)
90
m
m
72mm
48
m
m
48 mm
DR
ILL
ÿ3
mm
x4
Box 2
For
Active X-S
TO ACTIVE X
ANTENNA
TO ACTIVE X-S
ANTENNA
TO EXTERNAL
ALARM
+12v
Box 1 (Standard)
Box 2 (Standard)
SHIPS
SUPPLY
+12v
Fig. 7: Connection of External Alarm
For further information on wiring external alarms, see the
Active-X and ActiveX-S Operation Manuals
FIT SWITCH
WHEN USING
EXTERNAL
ALARM
SHIPS
SUPPLY
To Active XS
*
S
SHIPS
SUPPLY
Note: Either of the two external alarm terminal options
marked
can be used.
Only one control box can be used to indicate S-Band
operation by attaching the yellow/green wire to either of
the connections marked
above but not both.
✣
✣
✣
✣
✣
✣
To Active X-S
Box 1 (Standard)
Box 2 (Waterproof)
*
*
*