OPERATION
SRM-2620U
32
X7502341900
© 10/2016 ECHO Inc.
Move stop switch button
(A) forward away from the
STOP position.
2.
Purge Bulb
Pump purge bulb (C) until
fuel is visible in the “Clear”
fuel return line.
Note: Lightly place knee
on drive shaft to
stabilize unit during
starting. Do not
apply excessive downward force or damage to unit can occur.
3.
Recoil Starter
Lay the unit on a flat area
and keep movable
attachment parts clear of
all obstacles. Firmly grip
throttle handle and throttle
trigger lockout with left
hand. Rapidly pull recoil
starter handle/rope (D)
until engine fires.
Note: If engine does not
start after 5 pulls,
use Cold Start Procedure.
Stopping Engine
1.
Throttle
Release throttle trigger and allow
engine to return to idle before
shutting off engine.
2.
Stop Switch
Move stop switch button (A)
backward to STOP position.
B
C
D
A