12
A
O
PERATION
• Provide all operators of this equipment with the Operator's Manual
and instructions for safe operation.
• Check unit for loose nuts, bolts and screws daily.
• Recoil starter: Use short pulls - only 1/2-2/3 of rope length for
starting. Do not allow the rope to snap back in. Always hold the unit
firmly.
• Rotate spring loaded throttle handle downward to a comfortable
operating position.
STARTING
COLD
ENGINE
1.
Move throttle lever (A) to START/IDLE DETENT position.
2.
Close Choke - Cold Start.
Move choke (B) to "Cold Start" Position.
3.
Primer Bulb -Prime.
Pump primer bulb (D) until fuel is visible and flows freely in the
clear fuel tank return line. Pump bulb an additional 4 or 5 times.
4.
Pull recoil starter handle (E) 4 (four) times or until engine fires.
5.
Open choke (B) and if necessary, restart engine.
NOTE
Allow engine to warm up before use.
E
B
C
D
Summary of Contents for PB-261L
Page 22: ...22 NOTES...