10. Maintenance Procedures
Follow all safety instructions. See
Safety Instructions
.
10.1. General Inspection and Cleaning
During periods of wet weather, perform inspection and cleaning once per day.
1)
Move the power switch to the OFF position.
2)
De
‐
energize AC power at the mains (charging station only).
3)
Remove robot from charging station (if required).
4)
Visually inspect the unit, replace damaged components.
5)
Check all electrical connectors, reconnect if necessary.
6)
Use a plastic scraper, nylon brush, compressed air, or a damp cloth to clean dirt, grass, sticks, or
obstructions.
NOTE
:
Do not use a high
‐
pressure washer or running water for cleaning.
Never use solvents.
10.2. Cold Weather Storage (as installed)
1)
Move the power switch to the OFF position.
2)
De
‐
energize AC power at the mains.
3)
Cover the charging station with a non
‐
conductive, waterproof barrier.
10.3. Cold Weather Storage or Moving (removed from installation)
1)
Move the power switch to the OFF position.
2)
De
‐
energize AC power at the mains.
3)
Remove the M5 nuts (8X) from the base of the enclosure top. Save the nuts for reassembly.
4)
Remove the AC wires (neutral
‐
white, line
‐
black, ground
‐
green) from the terminal block.