background image

 

IO5 PD

IO6 PD

IO0 T2IN

FON PD

JP203

.   

I/O Connector 

The following figure shows the I/O connector pinout for the FT 6000 EVB board.  You can use this 

connector to attach custom I/O devices to an evaluation board.    

VDD_GIZMO

IO4

VDD5

IO5

VA (PWR_IN)

IO1

CP0

IO3

SVC-

CP2_TX

IO2

VDD5_EXT

IO11

IO10

TP1

1

IO7

GIZ

MO

Inte

rfa

ce

CP4

RST-

CP1

IO0

CP3_RX

IO6

P201

HEADER 17X2

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34

IO9

IO8

 

Design and Test for Electromagnetic Compatibility 

Echelon’s free topology twisted pair technologies support the creation of products that meet a wide 

variety of regulatory requirements.  Chapter 4 of the 

FT 6000 Smart Transceiver Data Book 

describes 

how to create products with Echelon’s free topology twisted pair technology that meet electromagnetic 

compatibility regulations. 
The FT 6000 EVB boards are designed to facilitate testing of Echelon’s free topology twisted pair 

technologies.  As such, they have no enclosure, providing open access to the IO connectors, buttons, 

LEDs, and other I/O components.  They have been developed to allow consumer and commercial 

device OEM suppliers to evaluate the technology quickly, and have not been designed to be installed 

permanently

 

in homes or commercial buildings.  If you work with the FT 6000 EVB boards in a home 

22 

FT 6000 EVB Hardware Details 

Summary of Contents for FT 6000

Page 1: ...078 0504 01A Develop prototype test and debug applications using the FT 6000 EVB FT 6000 EVB Hardware Guide...

Page 2: ...and referenced in this document have been described for illustrative purposes only and may not have been tested by Echelon It is the responsibility of the customer to determine the suitability of the...

Page 3: ...ons and LEDs 8 Jumper Settings 9 In Circuit Programming of the External Serial Memory Device 9 I O Line Access JP24 11 LCD Light Sensor LEDs Switch Joystick Connections JP31 12 Switch Joystick Tempera...

Page 4: ...cks modules routers and management software The FT and Neuron 6000 family of chips enable the creation of the most compact and cost effective IzoT capable devices The FT 6000 EVB is a complete Series...

Page 5: ...board using the serial peripheral interface bus SPI interface Purpose This document describes how to connect the FT 6000 EVB boards and it describes the Neuron core I O devices service pin and reset...

Page 6: ...232C CRT terminal FT 6000 EVB Examples Guide Describes how to run the Neuron C example applications included with the IzoT NodeBuilder Development on an FT 6000 EVB I O Model Reference for Neuron Chip...

Page 7: ...r e mail from your closest Echelon support center The contact information is as follows Region Languages Supported Contact Information The Americas English Japanese Echelon Corporation Attn Customer S...

Page 8: ...Region Languages Supported Contact Information Other Regions English Japanese Phone 1 408 938 5200 Fax 1 408 328 3801 lonsupport echelon com viii Preface...

Page 9: ...1 Connecting the FT 6000 EVB Hardware This chapter describes how to power your FT 6000 EVB and connect it to your development computer FT 6000 EVB Hardware Guide 1...

Page 10: ...1 3 Install the software included with your development kit on your computer Follow the instructions in the IzoT FT 6000 EVK Quick Start Guide to install the software included with your EVK The develo...

Page 11: ...guides you through all the steps of creating a device with the IzoT NodeBuilder tool including creating the NodeBuilder project the device template the device interface and the Neuron C code that imp...

Page 12: ...f installation ISI mode by default You install and connect this example application and the other examples using the OpenLNS Commissioning tool or using the ISI protocol See the FT 6000 EVB Examples G...

Page 13: ...2 FT 6000 EVB Hardware Details This chapter describes the Neuron core service pin and reset buttons and LEDs I O devices and jumper settings on the FT 6000 EVB hardware FT 6000 EVB Hardware Guide 5...

Page 14: ...rnal 10 MHz crystal you can adjust the system s internal clock speed from 5MHz to 80MHz an FT X3 communication transformer and an external serial flash non volatile memory device For details on the FT...

Page 15: ...Transceiver IO2 pin when jumper pins 9 10 on JP31 are connected LED2 is connected to the IO3 pin when jumper pins 11 12 on JP31 are connected Temperature Sensor The FT 6000 EVB includes a temperature...

Page 16: ...ite at www3 alps com WebObjects catalog woa E HTML Switch Tact SKQU SKQUAAA010 html Service Pin and Reset Buttons and LEDs The FT 6000 EVB includes a Service button and a Reset button that have corres...

Page 17: ...rt loading application images through third party device programmers or memory ICE Echelon has tested a third party in circuit programmer the Aardvark I2C SPI USB Host Adapter from TotalPhase as descr...

Page 18: ...the FT 6000 EVB follow these steps 1 Power off the FT 6000 EVB 1 Plug the Aardvark programmer pod s ribbon cable connector into the EVB s shrouded header JP23 The ribbon cable connector and JP23 are p...

Page 19: ...extension must be renamed to HEX for the FlashGui software to recognize the file 4 Power down the EVB remove the Aardvark connector from JP23 and power up the EVB I O Line Access JP24 This header pro...

Page 20: ...oystick Connections JP31 This set of jumpers is used to connect the LCD Light Sensor LEDs and the shift register for the SW2 push button lines 1 and 2 of three and joystick SW3 on the FT 6000 EVB The...

Page 21: ...Device Functionality on FT 6000 EVB 1 2 IO0 SCL LCD 3 4 IO0 SCL L Light sensor 5 6 IO1 SDA LCD 7 8 IO1 SDA L Light sensor 9 10 IO2 LED1 11 12 IO3 LED2 13 14 IO4 SWCLK Shift register clock for SW2 and...

Page 22: ...hat connects the I O line to an I O device on the FT 6000 EVB 8 R10 4 R20 1 R30 10 T1IN 5 PD 6 PD 0 T2IN FON PD 6 SWSH 7 TEMP 8 RXUSB 9 SW1 10TXUSB 11 LINT 1 PD 9 PD 8 R10 4 R20 1 R30 10 T1IN 5 PD 0 S...

Page 23: ...ts or diagnosis Once you create this USB connection you can output debugging and tracing information from the device application running on your FT 6000 EVB to a terminal emulation program on your com...

Page 24: ...program on your computer to monitor the serial output In addition you must specify code in your device application that outputs data to the interface For example the example applications included wit...

Page 25: ...Debug string You can view the source code for the FT 6000 EVB example device applications by clicking Start pointing to Programs pointing to Echelon NodeBuilder pointing to Examples pointing to FT 600...

Page 26: ...LCD 5V If you are not using the LCD and you want to reduce the power consumption of the FT 6000 EVB you can disconnect the LCD s power as illustrated in the following figure you can hang the shunt of...

Page 27: ...rface with handshake lines to connect your FT 6000 EVB to a development computer for performing application level debugging or to connect it to other microcontrollers Note When you connect the EIA 232...

Page 28: ...erminal emulation program on your computer to monitor the serial output Configure your terminal emulation program for direct connection to your serial port using the serial parameters specified in the...

Page 29: ...n the FT 6000 Smart Transceiver to the EIA 232 communications interface on the board IO10 is connected to pin 12 on the EIA 232 connector as a serial data output TX IO8 is connected to pin 14 as a ser...

Page 30: ...reation of products that meet a wide variety of regulatory requirements Chapter 4 of the FT 6000 Smart Transceiver Data Book describes how to create products with Echelon s free topology twisted pair...

Page 31: ...tandards apply in your region consult the appropriate regulatory agencies In the European Union CISPR 22 or equivalently EN 55022 applies In the North American market the FCC regulates emissions from...

Page 32: ...24 FT 6000 EVB Hardware Details...

Page 33: ...A Emulating an FT 6010 Board This appendix gives you the instructions for using the FT 6050 EVB to emulate an FT 6010 board FT 6000 EVB Hardware Guide 25...

Page 34: ...may load the FT 6050 EVB with the FT 6010 image over the network as follows 1 Make sure that the EVB is loaded with the b6050V4 image version 21 02 03 or later 2 Load the b6010v4 evb ndl image using...

Page 35: ......