background image

The ECHO Tec. Membrane Element is guaranteed to be cleanable for a minimum of one year from date 
of  shipment,  provided  that  cleaning  instructions  are  adhered  to  and  foulant  is  acid  soluble  metal 
hydroxides  and  calcium  carbonates  or  alkaline  soluble  organic,  inorganic  substances  and 
microbiological  slimes.    The  ECHO  Tec.  Membrane  Element  is  not  guaranteed  against  iron  fouling 
(rust),  chemical  attack,  extreme  temperatures  (over  120º  F/under  32ºF),  drying  out,  or  extreme 
pressures (over 1000 psig). 
 
 
Boat building or refurbishing is a timely process and unexpected delays can occur.   
ECHO  Tec.  Systems  are  normally  shipped  complete  with  Reverse  Osmosis  Membrane  Element(s).  
However,  if  the  ECHO  Tec.  System  will  not  be  put  to  use  within  9  months  of  shipment,  there  is  a 
potential  danger of the Reverse Osmosis Membrane Element(s) fouling or drying out.  Therefore, we 
can ship your system without the Membrane(s).  This allows you to install the system at the appropriate 
time  in  your  scheduled  production/refurbishing  without  damage  to  the  Reverse  Osmosis  Membrane 
Element(s).    We  will  ship  the  Reverse  Osmosis  Membrane  Element(s)  when  notified  that  the  ECHO 
Tec. System is ready for use.  This service is available upon request only. 
 
 
The  warranty  on  the  ECHO  Tec.  Watermaker  is  activated  upon  shipment  of  the  system  with  the 
Reverse Osmosis Membrane Element(s) pre-installed.  However, by shipping the watermaker without 
the  Reverse  Osmosis  Membrane  Element(s),  the  warranty  period  will  start  upon  shipment  of  the 
Reverse  Osmosis  Membrane  Element(s),  with  a  delay  of  12  months  maximum  from  the  date  of 
purchase. 
 
 

ECHO MARINE LTD. 

1

st

 Avenue South, 

Chaguaramas 
Trinidad W.I. 

 
 

TELEPHONE: 1-868-634-2027 

FAX: 1-868-634-2026 

E-MAIL: [email protected] 

 

 

www.ech2otec.com

 

Summary of Contents for Watermakers 200-BMS-1

Page 1: ...NUAL Pages 2 INTRODUCTION 3 SPECIFICATIONS 4 5 STANDARD SYSTEM FEATURES OPTIONS AND ACCESSORIES 6 FLOW DIAGRAM 7 9 INSTALLATION INSTRUCTIONS 10 INSTALLATION INSTRUCTIONS OPTIONS 11 13 SYSTEM OPERATION...

Page 2: ...st products on the market The purpose of this manual is to allow you to become familiar with each component of your new ECH2O Tec Watermaker By understanding the function importance and normal operati...

Page 3: ...rated performance is tested at 26 C 80 F water temperature and 33g NaCl ltr RO MEMBRANE TYPE Standard size high rejection TFC Polyamide thin film composite spiral wound single pass reverse osmosis ele...

Page 4: ...gh pressure gauge 1 Product flow meter 25 50 100gph 1 Diverter 3 way valve 1 Breaker 10amp or 2 Breakers 10 amp with optional boost pump 6 1 Hardener pH neutralizer kit with mineral element and 2pcs 3...

Page 5: ...al cartridge stainless steel bracket 8 screws shut off valve 2 x 5 8 hose barb connectors 10ft 1 2 braided hose 4 x 1 2 hose clamps Low pressure gauge The low pressure gauge indicates when the pre fil...

Page 6: ...ermakers DATE 31 05 06 REV 3 1 DRWN MS BOOST PUMP FRESH WATER FLUSH FILTER FILTER STRAINER FILTER PUMP FILTER 5 20 PSI PSI FLOW REJECT WATER REJECT WATER OUTLET CLEANING STORAGE SOLUTION INTAKE R O ME...

Page 7: ...ld only do the electrical installation Connect the wire of the magnetic clutch to the system switch on the control panel Supply 12V DC to the switch This wire needs to be protected by a 10A fuse When...

Page 8: ...h storage valve is supplied connect the 3 4 hose fitting on the tee to the bottom intake fitting of the high pressure pump INSTALL ALL PLUMBING TO ELIMINATE ANY AIR POCKETS IN THE SYSTEM CAUTION USE A...

Page 9: ...your water tanks into the R O membrane and does not require a new fitting in your tank When using a spigot as the taste test station be sure you have no shut off valves in the product water line A han...

Page 10: ...plied nylon nipple to the standard filter housing and reconnect the reinforced vinyl hose The 5micron cartridge has to be installed as the second filter in flow direction 5MICRON PRE FILTER HOUSING WI...

Page 11: ...Switch on the boost pump optional and the electro magnetic clutch 7 Flush the air out of the system Check the brine discharge at the output location Caution Never allow any leaks in your hose or tube...

Page 12: ...ow rate of your vessel s fresh water system pump 6 Close the seawater intake valve MEMBRANE STORAGE PROCEDURE If you intend to store your watermaker for more than 7 days growth of microorganism will d...

Page 13: ...bel CAUTION Do not mix different cleaning chemicals together Do not use different cleaning chemicals together at the same time Mix the cleaning chemicals separately and use them separately Note All cl...

Page 14: ...applicable When brushes are worn out High pressure pump Change crankcase oil Change packing seals and O rings Initial change after 50 hrs Every 200 operating hours or 6 months Every 5000 hrs or 2 year...

Page 15: ...s inner wall and remove it in one fast pull 6 Inspect the end plug for hairline cracks or damages on the O rings and O ring grooves 7 Pull the membrane on the product pipe out of the pressure vessel o...

Page 16: ...recommended lubricant SAE 90 gear box oil non detergent Check inlet lines for restrictions and or proper size Check strainer and filter s Inability to build up pressure Discharge valve chamber has ai...

Page 17: ......

Page 18: ...16B and copper gasket 16D and clean the old Locktite from the plunger bolt 16C and plunger base 16A Replace the plunger with the new one and Locktite the plunger bolt and torque to 120 inch pounds NOT...

Page 19: ...s 12A and 12B if they were removed from the crankshaft Be certain the bearings are pressed all the way onto the shaft and completely into the crankcase Replace radial shaft seal 11 bearing cover with...

Page 20: ...s Service Center The purchaser must pay any transportation or labor expenses incurred in removing and returning the product A return authorization must be obtained before any part or component is ship...

Page 21: ...nger of the Reverse Osmosis Membrane Element s fouling or drying out Therefore we can ship your system without the Membrane s This allows you to install the system at the appropriate time in your sche...

Reviews: