The ECHOTec Membrane Element is warranted to be cleanable for a minimum of one year 
from date of shipment, provided that cleaning instructions are adhered to and foulant is 
acid  soluble  metal  hydroxides  and  calcium  carbonates  or  alkaline  soluble  organic, 
inorganic substances and microbiological slimes.  The ECHOTec Membrane Element is not 
warranted  against  iron  fouling  (rust),  chemical  attack,  extreme temperatures  (over  120º 
F/49ºC and under 32ºF/0ºC), drying out, or extreme pressures (over 1000 psig/68bar). 

 

CAUTION:  Use of parts not supplied directly by Echo Marine (generic parts), including but 
not  limited  to  maintenance  parts,  pre-filter  elements,  cleaning  and  storage  chemicals, 
pump oil, spare parts, replacement parts, system components and or system accessories, 
shall void all warranties expressed or implied unless agreed in writing. 

 

ECHOTec  desalination  systems  are  shipped  complete  with  reverse  osmosis  membrane 
element(s)  installed.    However,  if  the  ECHOTec  system  will  not  be  put  to  use  within  10 
months  of  shipment,  there  is  a  potential  danger  of  the  membrane  element(s)  fouling.  
Therefore, we offer to ship your system without the membrane element(s).   This allows 
installing the desalination system at the appropriate refurbishing or production schedule 
without risk to the membrane element(s).  Echo Marine Ltd. will ship the reverse osmosis 
membrane  element(s)  when  notified  that  the  ECHOTec  desalination  system  is  ready  for 
commissioning.  This service is available upon request. 

 

The warranty on the ECHO Tec Watermaker is activated upon shipment of the system with 
the  reverse  osmosis  membrane  element(s)  installed.    However,  by  shipping  the 
watermaker without the reverse osmosis membrane element(s), the warranty period will 
start upon shipment of the membrane element(s), with a  maximum delay of 12 months 
from the date of purchase.

 

 

 

ECHO MARINE LTD. 

1st Avenue South, Chaguaramas, Trinidad W.I. 

Telephone: 1-868-634-2027   Fax: 1-868-6342026 

E-mail: [email protected] 

www.echotecwatermakers.com

 

 

Summary of Contents for 400-BMS-1

Page 1: ...tures Options and Accessories 6 Flow Diagram 7 10 Installation Instructions 11 Installation Instructions Options 12 13 System Operation Shut Down and Flush Procedure 14 Membrane Storage and Cleaning P...

Page 2: ...safe drinking water for many years to come if you follow the simple instructions in this owners guide The purpose of this manual is to allow you to become familiar with each component of your new ECH...

Page 3: ...ce is tested at 26 C 80 F water temperature and 33g NaCl ltr RO MEMBRANE TYPE Standard size high rejection TFC Polyamide thin film composite spiral wound single pass reverse osmosis element PRODUCT WA...

Page 4: ...1 Pressure control valve 1 High pressure gauge 1 Product flow meter 1 Diverter 3 way valve 1 Breaker without boost pump or 2 Breakers with boost pump 6 1 Hardener pH neutralizer kit with mineral eleme...

Page 5: ...as a second filter in flow direction Maintenance Kit 10 Pre filters 5 and or 20 microns 1 Spare sea strainer screen 2 Active carbon filters fresh water flush 1ltr High pressure pump oil Extended Maint...

Page 6: ...6 FLOW DIAGRAM Shown with Optional Equipment...

Page 7: ...225 RPM The high pressure pump can run on lower RPM This will decrease the specified production only Position the high pressure pump horizontal with the dipstick up The pump can turn in either directi...

Page 8: ...mechanical stress do not mount the sea strainer directly to the sea cock Connect the barbed fittings with the supplied coil reinforced intake hose and secure all hoses below water level with two hose...

Page 9: ...ne housing to the pressure control valve in the control panel Do not over tighten the high pressure fittings They are O ring sealed and need little torque to lock only CAUTION When connecting the high...

Page 10: ...alizer housing at a serviceable location in line with the product water tubing from the diverter valve on the control panel to the freshwater storage tank Refer to flow diagram on page 6 Note Observe...

Page 11: ...a screwdriver The only moving part in the pump other than the motor is the impeller magnet assembly This assembly rotates on a stationary spindle and up against a thrust washer Note The boost pump inc...

Page 12: ...eaning storage valve to the pre filter position towards the filter 4 Set the diverter valve to sample position left 5 Switch on the boost pump optional 6 Switch on the high pressure pump 7 Flush the a...

Page 13: ...he brine at the outlet becomes fresh PRE FILTER BACKWASH PROCEDURE As part of a long term storage you may remove the pre filter cartridges from the housings or perform a pre filter backwash procedure...

Page 14: ...cleaning of the membrane will reduce the performance of your water maker A drop in production of approximately 10 is normal and expected during the first year of operation Note Do not clean when prod...

Page 15: ...PSI No Boost pump pressure lower than 5 Hg Hardener pH neutralizer Replace or refilled with the mineral mix of another cartridge when 25 of the content has been dissolved to guaranty sufficient conta...

Page 16: ...agnetic clutch slips Tighten all hose clamps Reseal NPT fittings Move through hull fitting to lower location Bad electrical contact Test voltage directly at clutch connection when clutch is engaged Ex...

Page 17: ...e pliers pull the membrane element on the product tube in flow direction 6b Push out the remaining end plug from the opposite side with a pipe boat hook etc If the product port is mounted on the high...

Page 18: ...urn ring 25 pressure ring 24 and V sleeve with support ring 23 from the valve casing 26 Remove the V sleeve 23 from the seal case 20 Inspect all parts including O ring 21 for wear and replace if neces...

Page 19: ...otate the seal case as well so that the weep holes are down at the six o clock position Change the oil fill and the oil drain plugs Refer to the repair instructions as necessary for the proper assembl...

Page 20: ...ho Marine Ltd will repair or replace at its option the product or component therein which upon examination by Echo Marine shall appear to be defective or not up to factory specifications To obtain war...

Page 21: ...rse osmosis membrane element s installed However if the ECHOTec system will not be put to use within 10 months of shipment there is a potential danger of the membrane element s fouling Therefore we of...