SPECIFICATIONS
RATED PERFORMANCE:
ECHO Tec: 1000 – BHL – 2
min. 38 gallons – 143ltr. / hour
1300 – BHL – 3
min. 60 gallons – 227ltr. / hour
1800 – BHL – 4
min. 75 gallons – 284ltr. / hour
Reverse Osmosis performance varies with the feed water temperature and salinity.
The rated performance is tested at 26
°
C / 80
°
F water temperature at a salinity of 35g/l.
A decrease in product water quantity of 10 to 15% in the first year is normal and
expected.
RO MEMBRANE TYPE:
Standard size high rejection TFC Polyamide, thin film composite, spiral wound, single
pass reverse osmosis element.
SALT REJECTION:
min. 99.5%
SALINITY RANGE:
up to 33,000 ppm TDS ( NaCl )
PH RANGE:
4 – 11
CHLORINE TOLERANCE:
1000 ppm hours
OPERATING PRESSURE:
725 to 800 psi (continuous duty)
FEED WATER PRESSURE:
0 to 60 psi
FEED WATER TEMPERATURE RANGE:
min. 33
°
F / 0.5
°
C, max 113
°
F / 45
°
C
ELECTRICAL POWER REQUIREMENTS:
115/230V 60Hz - 230V 50Hz single phase 11.2amps at 230V
208 - 230/460V 60Hz three phase 5.5apms at 220V
220/380/440V 50Hz three phase 3.8amps at 380V
SAFETY SWITCH OFF FUNCTIONS:
1) High RO pressure: above 1000 PSI
2) Low high-pressure pump feed pressure: below 1.5 PSI
3) High product salinity (optional)