M335 Microstepping Driver Manual V1.0
ECG--
SAVEBASE
8
4.2
Current Settings
Output current is set by SW3, 24of the DIP switch as shown in the following table:
SW3
SW4
Full Current
Auto Half Current
Peak Current
RMS
Peak Current
RMS
OFF
OFF
3A
2.14A
1.5A
1.07A
ON
OFF
2.25A
1.6A
0.6A
0.42A
OFF
ON
1.5A
1.07A
1.5A
1.07A
ON
ON
0.6A
0.42A
0.6A
0.42A
Note:
Output current is automatically switched to 50% after signal pulse stop for about 0.4
seconds (according to the table settings). This can make the motor and drive heating reduction,
improved reliability. Theoretically 25% reduction in the heat (heat is proportional to the square of
the current).
4.3
Decay Mode Settings
With the decay mode from 0% to 100%, the attenuation increases. Users can eliminate the stepper
motor locked noise and improve motion stabilization by switch SW5, SW6.
SW5
SW6
Decay Mode
OFF
OFF
No Decay
ON
OFF
Slow Decay
OFF
ON
Medium Speed Decay
ON
ON
Fast Decay
5
Power supply selection
The M335 can match medium and small size stepping motors (from NEMA size 14 to 23) .To