The full coil configuration on a six lead motor should be  used in applications where 
higher torque at lower speeds is desired. This configuration is also referred to as full 
copper. In full coil mode, the motors should be run at only 70% of their rated current 
to prevent overheating. 

 

Figure 6.2-2 6-lead motor full coil (higher torque) connections

 

6.3

 

Connections to 8-lead Motors 

8  lead  motors  offer  a  high  degree  of  flexibility  to  the  system  designer  in  that  they  may  be 

connected in series or parallel, thus

 

satisfying a wide range of applications. 

Series Connections

 

A  series  motor  configuration  would  typically  be  used  in  applications  where  a  higher  torque  at 

lower speeds is required. Because

 

this configuration has the most inductance, the performance will 

start  to  degrade  at  higher  speeds.  In  series  mode,  the  motors

 

should  also  be  run  at only  70%  of 

their rated current to prevent overheating. 

 

Figure 6.3-1 8-lead motor series connections

 

Summary of Contents for M335

Page 1: ...M335 Microstepping Driver Manual V1 0 ECG SAVEBASE EMAIL EBAY SAVEBASE COM WEB HTTP STORES EBAY CO UK SAVEBASE User Manual of M335 High Performance Microstepping Driver...

Page 2: ...hird party use it is their responsibility to maintain certify and comply the end user products built base on out components sold on this website or other Easy Commercial Global sales resources Assembl...

Page 3: ...res Low cost Low noise and high speed 1 2 8 16 adjustable micro step control for more accurate and smoother motor running Supply voltage up to 30V DC Output current up to 3 5A Single chip PWM bipolar...

Page 4: ...Environment Environment Avoid dust oil fog corrosive gas Ambient Temperature 0 50 Operating Temperature 70 158 F Humidity 40 90 RH9 Vibration 5 9m S2 Max Storage Temperature 20 125 Weight Approx 200g...

Page 5: ...k Current Interface Description Pin Function Details PUL 5V Pulse signal Single pulse pulse direction mode 4 5V when PLU HIGH 0 0 5V when PUL LOW For reliable response pulse width should be longer tha...

Page 6: ...ses coupled onto the drive control signals We recommend to use line driver control signals to increase noise immunity of the driver in interference environments In the following figures connections to...

Page 7: ...M335 Microstepping Driver Manual V1 0 ECG SAVEBASE 5 Figure 3 3 1 Connections to open collector signal common anode Figure 3 3 2 Connection to PNP signal common cathode...

Page 8: ...ect direction 3 t3 Pulse width not less than 1 5 s 4 t4 Low level width not less than 1 5 s 3 5 Wiring Notes In order to improve anti interference performance of the driver it is recommended to use tw...

Page 9: ...ck EMF voltage surge which may damage the driver 4 Selecting Microstep Resolution Decay mode and Driver Output Current This driver uses a 6 bit DIP switch to set micro step resolution motor operating...

Page 10: ...stop for about 0 4 seconds according to the table settings This can make the motor and drive heating reduction improved reliability Theoretically 25 reduction in the heat heat is proportional to the s...

Page 11: ...current The reason is that the driver draws current from the power supply capacitor of the unregulated supply only during the ON duration of the PWM cycle but not during the OFF duration Therefore the...

Page 12: ...full coil uses the full windings of the phases Half Coil Configurations As previously stated the half coil configuration uses 50 of the motor phase windings This gives lower inductance hence lower tor...

Page 13: ...s 6 3 Connections to 8 lead Motors 8 lead motors offer a high degree of flexibility to the system designer in that they may be connected in series or parallel thus satisfying a wide range of applicati...

Page 14: ...tion offers a more stable but lower torque at lower speeds But because of the lower inductance there will be higher torque at higher speeds Multiply per phase or unipolar current rating by 1 96 or the...

Page 15: ...M335 Microstepping Driver Manual V1 0 ECG SAVEBASE 13 7 Frequently Asked Questions...

Reviews: