Indoor water heaters must be installed
with CAT III vent pipe in acc ordance with
vent supplier/ Manufacturer in accordance
with local code. Owner must refer to vent
manufacturer’s instructions and
specifications. Z-Flex information can be
found at www.novaflex.com, please refer
to page 18 for additional links.
A. BACK INSTALLATION
1. Insert the vent pipe through the
installation holes in the wall with the terminal
sticking out.
2. Connect the elbow to the vent pipe and
water heater, moving straight backwards
until the expansion screws go into the holes
of the water heater. Screw the nuts tight
(pay attention to the direction of the elbow).
B. SIDE INSTALLATION:
1. Aim the holes in the water heater onto
the expansion screws, hang it up and screw
the nuts tightly.
2. Put the vent pipe through the holes in the
wall, and connect the elbow with the water
heater and vent pipe.
C. VERTICAL INSTALLATION
Please refer to local installation professional
or venting manufacturer:
The installation hole in the wall needs to
be sealed by fire-retardant material or wall
thimble, making sure the water heater is tight
and will not come off.
Make sure the location of the water heater allows for easy access
and operation.
In case of dry wall or concrete wall use dry wall anchors or lag bolts.
The water heater requires 120VAC/ 60Hz. Have a receptacle with
ground terminal near the water heater. The length of the power
supply cord is 5 feet.
Drill the holes as per the sizes in the figure to the left, put 2
expansion screws into the top holes, and 2 rubber screws into the
bottom holes.
Hang up the water heater, tighten the expansion screws, and put 2
wood thread screws into the bottom holes.
CAUTION: Reinforcement of the wall is
required in case the wall is not strong enough
to hold the water heater.
Back Installation
Sealant
Side Installation
3.9”
4.8”
5.5”
3.9”
2.9”
4.8”
3.9”
5.5”
Mounting
Installation