13
TROUBLESHOOTING GUIDE
SYMPTOM
POSSIBLE CAUSE
CORRECTIVE ACTION
Unit “Clicks” periodically when
no hot water is being used
Cold water use causes reverse
flow through heater.
Unit has been in standby for
an extended period with no hot
water use.
Install check valve on outlet
NORMAL OPERATION. Unit will
activate as needed to maintain
a reference temperature to
ensure a quick start-up on the
next use.
Hot water supply is warm but
does not get HOT!
FLOW is too high.*
ONE OF THE MAIN POWER
BREAKERS may be tripped.
BAD Element or Sensor.
Reduce flow.
Check power panel. Reset
breaker if tripped.
Call local service contractor.**
Hot water supply is COLD!
FLOW is too high.*
HIGH TEMPERATURE LIMIT
SWITCH may be tripped.
ONE OF THE MAIN POWER
BREAKERS may be tripped.
BAD Heating Element or
Temperature Sensor.
CIRCUIT BOARD failure.
Reduce flow.
Verify if Limit Switch is tripped.
Reset if tripped.
Check power panel. Reset
breaker if tripped.
Call local service contractor.**
Call local service contractor.**
Hot water temperature
fluctuates.
FLOW is too high.*
ONE OF THE MAIN POWER
BREAKERS may be tripped.
BAD Heating Element.
BAD Temperature Sensor.
Reduce flow.
Check power panel. Reset
breaker if tripped.
Call local service contractor.**
Call local service contractor.**
* Do not attempt to fill a large bathtub at full faucet flow. Tub faucets are designed to dump hot
water from a storage tank heater to maximize the useful quantity available. Your Eccotemp will take
longer to fill a tub, especially in the cooler months of the year but you will have continuous hot water
for as long as you wish to bathe for as many baths as you desire.
** Check listings in your area for local Heating & Plumbing or Appliance Repair companies for labor
estimates. Check for Warranty coverage on labor charges. For further assistance, call Eccotemp at
866-356-1992, Eastern Time, during regular business hours for available parts, diagnostics and repair
information or email [email protected].