- 5 -
Air electrostatic spray gun
Model
LP6000W/S/M
Maximum voltage to be charged
DC -60kV
Shorting current
80μA
Fluid pressure
Normal
0 to 0,3MPa
Max.
0,62MPa
Air pressure
Normal
0.05 to 4MPa
Max.
0.62MPa
Air consumption
Max. 150L/min (normal)
Outside dimensions
L207 × W55 × H219 (mm)
Weight
(excl. cable, hose and nozzle)
545g (W/SM)
Connecting cable length
10m (extendable up to 30m in increments of 10m)
Standard
Machinery Directive 2006/42/EC
Low-Voltage Directive 2006/95/EC
EMC Directive 2004/108/EC
ATEX Directive 94/9/EC
EN 50050:2001
Certification
Sira 10ATEX5053X
Sira Test & Certification Ltd.
Rake Lane, Eccleston
Chester, CH4 9JN, England
※
The cable length can be extended up to 30m by combining the extension and connecting cables.
Be very cautious in the use of a paint heating system. Material paint must be supplied at the
temperature not exceeding 40
C. To high a temperature may cause the paint tube to soften and
disconnect.
Material supply system and fluid regulator:
Please refer to separate instruction manuals for each item.
Paint Materials should be used under pressures not to exceed 0. 6MPa.
If in doubt as to the selection of the proper material supply pump or system, please consult with
3
Specifications
CAUTION