background image

Seite 2 von 3

P/N 920-5110-00 (Rev F) 2019-07-04 

Modus

Muster

Beschreibung

Sync

P1

ECE R65 Einzelblitz A. 

123 SFPM Phase A

JA

P2

ECE R65 Einzelblitz B. 

123 SFPM Phase B

JA

P3

ECE R65 Einzelblitz ABWE. 

123 SFPM Alternierend

JA

P4

ECE R65 Doppelblitz A. 

123 DFPM Phase A

JA

P5

ECE R65 Doppelblitz B.  

123 DFPM Phase B

JA

P6

ECE R65 Doppelblitz ABWE.

123 DFPM Alternierend

JA

Tipp-Dauer

 Funktion

0 – 1 Sek.

 NÄCHSTES MUSTER

1 – 3 Sek.

 VORHERIGES MUSTER

3 – 5 Sek.

 WERKSEINSTELLUNG (P4)

ÜBER 5 Sek.

 LETZTES MUSTER

BETRIEBSSPANNUNG

9 – 32 VDC

ANSPRECHSTROM

Max. 1,8A

LED-FARBE

Amber

Blau

Ro

Weiß

BETRIEBSTEMPERATUR

-30°C – +55°C

MAX. LUFTFEUCHTIGKEIT 95%

MUSTER

7 Blinkmuster (inkl. Cruise)

Kabelfunktion

Rotes Kabel = +VDC: Schwarzes Kabel = -VE: 

Blau (bis -VE) = Musterwechsel, Blau (bis +VE) = 

Dimfunktion: Gelb = Synchronisieren & Cruise

Blinkmuster:

Durch kurzzeitiges Berühren des blauen Kabels mit Negativ, wie im Abschnitt Kabelfunktion‟ beschrieben, können die Geräte so 

konfiguriert werden, dass sie wie die nachstehend aufgeführten Muster (in derselben Reihenfolge wie unten) blinken. Um eine 

Musterauswahl zu ermöglichen, muss die LED über die schwarzen und roten Kabel mit Strom versorgt werden.

ECE-Regelung 10 (Elektromagnetische Verträglichkeit)

Dieses Produkt wurde gemäß ECE REG 10 auf elektromagnetische Verträglichkeit geprüft. Zur Durchsetzung der Einhaltung dieser Verordnung 

ist es erforderlich, dass eine gute Installationspraxis befolgt und die Installation von einem qualifizierten Elektriker durchgeführt wird. Das 

Versorgungskabel sollte nicht in der Nähe von anderen empfindlichen Kabeln (z. B. Funkantenne, ABS-System usw.) verlaufen. Falls dies nicht 

möglich sein sollte, sollten die Kabel im rechten Winkel zu einander geführt werden, um eine Kopplung zu minimieren.
Zur Montage der Lampe müssen vier M5-Lochungen in der gewünschten Position im Fahrzeug gebohrt werden, passend zu den vier 

Befestigungslöchern der SecuriLED. Eine weitere Bohrung ist erforderlich, damit das Kabel in das Fahrzeug eingezogen werden kann (siehe 

Diagramme 1 und 2 für Abmessungen). Das SecuriLED wird mit Hilfe der vier M5 Schrauben und Muttern, wie in der Abbildung unten gezeigt, und 

mit der Dichtung zwischen SecuriLED und Fahrzeug montiert. Empfohlenes Anzugsdrehmoment – 1,5 Nm.

Schlüssel

SFPM

Einzelne Blitze pro Minute (Single 

Flashes Per Minute)

DFPM

Doppelblitze pro Minute (Double 

Flashes Per Minute)

M5 Screw

M5 Nut

Gasket

Panel

Diagram 1.

SecuriLED Synchronisation Wiring Diagram

Summary of Contents for SecuriLED II ED5110A

Page 1: ...ould be damaged INSTALLATION OPERATING INSTRUCTIONS SecuriLED II DIRECTIONAL The SecuriLED II are the new generation of Directional LED lamps following the very successful launch of Delta Design Secur...

Page 2: ...rder below by momentarily making contact with the blue wire and the negative as described in the wiring section The LED head must be powered through the black and red wires to allow pattern selection...

Page 3: ...ENTATIONS ABOUT THE PRODUCT DO NOT CONSTITUTE WARRANTIES Remedies and Limitation of Liability MANUFACTURER S SOLE LIABILITY AND BUYER S EXCLUSIVE REMEDY IN CONTRACT TORT INCLUDING NEGLIGENCE OR UNDER...

Page 4: ...Connecter la masse pour la fonction cruise C ble noir C ble rouge C ble bleu C ble jaune Les fonctions du c ble sont les suivantes tous les fils inutilis s couper ou isoler INSTALLATION ET FONCTIONNEM...

Page 5: ...et le n gatif comme d crit dans la section de c blage La t te DEL doit tre aliment e par les fils noir et rouge pour permettre la s lection de la s quence ECE R glement 10 Compatibilit lectromagn tiq...

Page 6: ...es de responsabilit LA SEULE RESPONSABILIT DU FABRICANT ET LE RECOURS EXCLUSIF DE L ACHETEUR EN CAS DE RESPONSABILIT CONTRACTUELLE D LICTUELLE Y COMPRIS LA N GLIGENCE OU AUTRE CONTRE LE FABRICANT CONC...

Page 7: ...n die auf Phase B eingestellt sind Cruise Dauerlicht Modus Anschluss ber Masse Schwarzes Kabel Rotes Kabel Blaues Kabel Gelbes Kabel Kabelfunktionen nicht benutzte Dr hte abschneiden oder isolieren IN...

Page 8: ...ten Kabel mit Strom versorgt werden ECE Regelung 10 Elektromagnetische Vertr glichkeit Dieses Produkt wurde gem ECE REG 10 auf elektromagnetische Vertr glichkeit gepr ft Zur Durchsetzung der Einhaltun...

Page 9: ...ESSLICHE RECHTSBEHELF VON SEITEN DES K UFERS BEI SCH DEN EINSCHLIESSLICH FAHRL SSIGKEIT ODER IM RAHMEN ANDERER THEORIEN GEGEN DEN HERSTELLER IM ZUSAMMENHANG MIT DEM PRODUKT UND DESSEN VERWENDUNG BESCH...

Page 10: ...ustadas a Fase B Funci n de crucero Conectar al negativo para el modo de crucero Cable negro Cable rojo Cable azul Cable amarillo La funci n de los cables es la siguiente cualquier cable no utilizado...

Page 11: ...l y negativo como se describe en el apartado sobre cableado Para permitir la selecci n de patrones el cabezal del LED se debe alimentar a trav s de los cables negro y rojo Reglamento ECE 10 Compatibil...

Page 12: ...NICA RESPONSABILIDAD DEL FABRICANTE Y LOS NICOS DERECHOS Y ACCIONES DEL COMPRADOR DE FORMA CONTRACTUAL O EXTRACONTRACTUAL INCLUIDA NEGLIGENCIA O SEG N CUALQUIER OTRA TEOR A CONTRA EL FABRICANTE EN REL...

Reviews: