Page 3 of 4
P/N 920-0323-00 (Rev B) 2018-07-17
© 2018 at Electronic Controls Company
Important!
Disable power before wiring up the Minibar.
Figure 2
BLACK
YELLOW
GREEN
SYNC SELECT (ISOLATE WHEN NOT IN USE)
VIOLET
NIGHT DIM SELECT (ISOLATE WHEN NOT IN USE)
Flash Pattern Chart
Sequence
Description
1
R65 Quad (Default setting)
2
R65 Double
3
R65 Burst
4
Double A
5
Double B
6
Quad A
7
Quad B
8
Quad SS (side to side)
9
Quad X (cross pattern)
10
Double SS
11
Double X
12
Quint A
13
Quint B
14
Quint SS
15
Quint X
16
Burst A
17
Burst B
18
Fast Rotate
19
Rotate Quad
20
Wave Rotate
21
Steady On
The wiring for the permanent mount minibar is as shown in
Figure 2. All wiring should be a minimum of 18AWG. The
positive line must have a 5 amp fuse, as shown. A switch
may be used to control the on/off function.
For SYNC flash operation between two permanent mount
minibars, connect the green wire from each lightbar together
(Isolate the wire when not in use).
For NIGHT DIM operation, connect the violet wire to positive
supply. (Isolate the wire when not in use).
Wiring Connections:
Permanent mount minibars
Flash patterns can be selected on permanent mount minibars
by touching the yellow wire to the red power wire for less than
a second. Contacting the yellow and red wires for longer
than a second toggles to the preceding flash pattern.
Magnetic mount minibars
Flash patterns can be selected on magnetic mount minibars
by pressing cigarette plug toggle switch for less than a
second. Holding the cigarette plug toggle switch for longer
than a second toggles to the preceding flash pattern.
Flash Mode Selection: