Wiring Instructions:

Important!

 

 This unit is a safety device and it must be

connected to its own separate, fused power point to assure its 

continued operation should any other electrical accessory fail.

Wire as shown in FIGURE 1.  All wiring should be a minimum of 20 AWG.  The positive line must have a slow blow 3 amp fuse.  Routing the ground wire 

directly back to negative battery terminal is recommended.  Pack dielectric grease, such as Dow Corning 4, around each electric connection exposed to 

moisture or the ambient environment.  Isolate any unused wires.

FIGURE 1

RED - POSITIVE

FUSE (3A) 

(USER SUPPLIED)

 BLUE - FLASH PATTERN SELECT 

(MOMENTARY TO 

GROUND), DIM (TO POSITIVE)

SWITCH 

(USER SUPPLIED)

YELLOW (SYNC)

BLACK - GROUND

SWITCH 

(USER SUPPLIED)

WHITE -

POSITIVE

(DUAL

COLOR ONLY)

SWITCH 

(USER SUPPLIED)

ORANGE - 

TAKEDOWN - 

POSITIVE

SWITCH 

(USER SUPPLIED)

GREEN - 

PUDDLE LIGHT - 

POSITIVE 

Summary of Contents for ED3777 Series

Page 1: ...yment area It is the responsibility of the user operator to determine a suitable mounting location ensuring the safety of all passengers inside the vehicle particularly avoiding areas of potential hea...

Page 2: ...Surface Mount 1 Select a flat mounting surface with the visibility of the flash and ease of wiring access taken into consideration 2 Using the unit or bracket as a template mark the two mounting hole...

Page 3: ...Routing the ground wire directly back to negative battery terminal is recommended Pack dielectric grease such as Dow Corning 4 around each electric connection exposed to moisture or the ambient enviro...

Page 4: ...ase2 yes Class 1 Class 1 120 120 140 N C N C Class 1 6 Single Flash 120FPM Alt yes N C N C N C N C N C N C N C N C 7 Double Flash 75FPM sim Phase1 yes Class 1 Class 1 140 140 160 80 Class B N C 8 Doub...

Page 5: ...ely Color 2 Synchronous Color 4 yes N C N C N C N C N C N C N C 20 20 36 Double 60FPM Color 1 Alternately Color 2 Alternately Color 3 Alternately Color 4 yes N C N C N C N C N C N C N C 21 37 Triple 7...

Page 6: ...CTURER REGARDING THE PRODUCT AND ITS USE SHALL BE AT MANUFACTURER S DISCRETION THE REPLACEMENT OR REPAIR OF THE PRODUCT OR THE REFUND OF THE PURCHASE PRICE PAID BY BUYER FOR NON CONFORMING PRODUCT IN...

Page 7: ...salir despedido lo cual puede causar lesiones graves o incluso mortales Consulte el manual del propietario del veh culo para conocer la zona de despliegue de los airbags El usuario u operador son resp...

Page 8: ...reducci n de la luz se necesita a adir un fusible 2A VERDE Operaci n de luz de suelo se necesita a adir un fusible 2A ROJO BLANCO PRODUCTO 1 Y 3 COLORES 2 Y 4 COLORES ED3777AW MBAR BLANCO ED3777BW AZU...

Page 9: ...REPRESENTANTE AUTORIZADO DEL FABRICANTE QUE HAGA REFERENCIA EN FORMA EXPRESA A ELLA Exclusi n de otras garant as EL FABRICANTE NO OTORGA NINGUNA OTRA GARANT A EXPRESA O IMPL CITA MEDIANTE LA PRESENTE...

Page 10: ...ou situ dans la zone de d ploiement d un airbag est susceptible de r duire l efficacit de cet airbag ou de devenir un projectile pouvant causer des blessures graves voire mortelles Reportez vous au ma...

Page 11: ...ec Pour la configuration pr c dente Entre 3 et 5 sec pour configuration d usine par d faut Plus de 5 sec valeur par d faut au motif no 13 ED3777 et motif no 12 ED3777XX MOUNTING SURFACE Surface de mon...

Page 12: ...SENTANT AUTORIS DU FABRICANT QUI FAIT EXPRESS MENT R F RENCE LA PR SENTE GARANTIE Exclusion d autres garanties LE FABRICANT N ACCORDE AUCUNE AUTRE GARANTIE EXPRESSE OU TACITE LES GARANTIES IMPLICITES...

Reviews: