background image

Page 2 of 4

Figure 1

Figure 2

Wiring:

`

All wiring should be a minimum of 22 AWG.  The positive line must have an in-line 3 amp slow-blow fuse for each directional as shown

in Figure 3.

Isolate unused wires individually.

NOTE: Male PL3 connector is needed but not required.  Cut female PL3 connector to hardwire the unit.

Synchronization:

ED3040 series are capable of syncing with other compatible ECCO products by following these steps:

1. Set the desired flash pattern on each unit individually.  It is also strongly recommended that the same style of flash pattern be used on all

    units to produce the most effective warning pattern. NOTE: Phases A and B for each style of flash pattern in the table denote the relative

    timing between units connected in a synchronizing installation.  To operate simultaneously, each unit must be set to the same phase 

    (A + A  or B + B); to operate alternately, units must be set to have the opposite phase (A + B or B + A).

2. Connect the yellow sync wires together and check that the units are flashing in a synchronized manner as expected.  If a pattern on one 

    unit appears incorrect, the blue pattern select wire can be used to cycle forward or backward on that individual unit until the correct 

    pattern is selected.  NOTE: This will only change the pattern in the one unit and will not affect the other units connected to the yellow sync

    wire.

Flash Pattern Selection:

The ED3040 series directionals can be configured to flash the following patterns by momentarily applying ground to blue wire.  The 

directional must be powered through the ground and power wires to allow pattern selection.

Figure 3

DIRECTIONAL

PL3 CONNECT

OR, FEMALE

PL3 CONNECT

OR, MALE

(USER SUPPLIED)

+

-

RED - POWER, COLOR 1

WHITE - POWER, COLOR 2

GRAY - REVERSE

YELLOW - SYNC

BLUE - FLASH PATTERN SELECT [MOMENTARY TO (-)]

RED W/ WHITE STRIPE - STOP/TURN

BROWN - TAIL

BLACK W/ WHITE STRIPE - GROUND

 STOP/TURN

TAIL

GROUND

IN-LINE FUSE

(USER SUPPLIED)

IN-LINE FUSE

(USER SUPPLIED)

IN-LINE FUSE

(USER SUPPLIED)

IN-LINE FUSE

(USER SUPPLIED)

SWITCH

(USER SUPPLIED)

IMPORTANT! This unit is a safety device and it must be connected to its own separate, fused power point to assure its continued operation 

should any other electrical accessory fail.

Summary of Contents for ED3040

Page 1: ...e properly grounded Inadequate grounding and or shorting of electrical connections can cause high current arcing which can cause personal injury and or severe vehicle damage including fire 4 Proper pl...

Page 2: ...the units are flashing in a synchronized manner as expected If a pattern on one unit appears incorrect the blue pattern select wire can be used to cycle forward or backward on that individual unit un...

Page 3: ...Double Color 1 Alternately Color 2 yes A 120 N C N C N C 19 19 35 Double Color 1 Alternately Color 2 yes B 120 N C N C N C 20 20 36 Double Color 1 Alternately Color 2 yes 120 N C N C N C 21 37 Triple...

Page 4: ...ANTY OR ANY OTHER CLAIM RELATED TO THE ECCO S PRODUCTS EXCEED THE AMOUNT PAID FOR THE PRODUCT BY BUYER AT THE TIME OF THE ORIGINAL PURCHASE IN NO EVENT SHALL ECCO BE LIABLE FOR LOST PROFITS THE COST O...

Page 5: ...ocar arcos de corriente alta lo que puede ocasionar lesiones personales o da os graves en el veh culo incluso un incendio 4 La colocaci n e instalaci n adecuadas son vitales para el buen funcionamient...

Page 6: ...incorrecto el cable azul de selecci n del patr n se puede utilizar para cambiar el patr n hacia delante o hacia atr s en esa unidad en particular hasta que se seleccione el patr n correcto Nota Esto...

Page 7: ...AS IMPL CITAS DE COMERCIABILIDAD O APTITUD PARA UN PROP SITO EN PARTICULAR QUE NO SE APLICAR N AL PRODUCTO EL NICO Y EXCLUSIVO REMEDIO DEL COMPRADOR CON RESPECTO AL CONTRATO DERECHOS POR DA OS O CUAL...

Page 8: ...xions lectriques peut provoquer l apparition d un arc lectrique haute tension susceptible de causer des blessures corporelles ou des dommages graves sur le v hicule ainsi qu un incendie 4 Une installa...

Page 9: ...vu Si l effet d une unit semble incorrect le fil bleu de s lection de l effet peut tre utilis pour faire d filer les effets pr c dents ou subs quents sur cette unit jusqu ce que l effet correct soit...

Page 10: ...TES DE QUALIT MARCHANDE OU D APTITUDE UN USAGE PARTICULIER SONT EXCLUES ET NE S APPLIQUERONT PAS AU PRODUIT LE SEUL ET UNIQUE RECOURS DE L ACHETEUR CONTRE LE FABRICANT CONCERNANT LE PRODUIT ET SON UTI...

Reviews: