background image

920-0149-00 Rev. K

Page 3 of 12

Figure 5

            

Note: The Magnet Mount is not recommended for use on a moving 

vehicle, nor is it intended as a permanent mount for the light.  Long 

duration usage of the magnet in the presence of moisture will cause 

the steel to rust.

Wiring:

The wiring for the permanent mount minibar is as shown in Figure 6.  All wiring 

should be a minimum of 18AWG. The positive line must have a 5 amp fuse, as 

shown.  A switch may be used to control the on/off function.

Figure 6

Flash patterns can be selected on permanent mount minibars by touching 

the yellow wire to the red power wire for less than a second.  Contacting 

the yellow and red wires for longer than a second toggles to the preceding 

flash pattern.  The VM models have flash pattern select via a momentary 

switch on the cigarette plug.

Flash Mode Selection:

The 5585 permanent mount models sync with other compatible ECCO 

products via the blue wire:

1.  Determine the desired style of flash pattern for each unit and   

     set each unit individually (without the BLUE wires connected

     together) to avoid confusion. It is also strongly recommended that 

     the same style of flash pattern be used on all units to produce the 

     most effective warning pattern. (NOTE: Phases A and B for each 

     style of flash pattern in the table denote the relative timing 

     between units connected in a synchronizing installation. To 

     operate simultaneously, each unit must be set to the same phase

     (A + A or B + B); to operate alternately, units must be set to have 

     the opposite phase (A + B or B + A)).

2.  Connect the BLUE (SYNC) wires together and check that the 

     units are flashing in a synchronized manner as expected. If a 

     pattern on one module appears to be wrong, the YELLOW

     (PATTERN SET) wire can be used to cycle forward or backward 

     on that individual unit until the correct pattern is selected. 

     Note: This will only change the pattern in the one unit and will 

     not affect the other units connected to the BLUE (SYNC) wire.

3.  If the blue wire is unused, leave unconnected and insulated.

Flash Pattern Syncing:

1.0" 

Figure 4

Flash Pattern Chart, Tabla de Patrones de Intermitencia, Flash Graphique de Motif

Sequence

Description

FPM

Phase

SAE J845

CA T13

5580A

5580CA

5585A

5587A

5585CA

5585CB

5585CC

5585CR

5585A

5585CA

5587CA

5585CB

5585CR

1

Quad (Default)

75

A

CLASS 2

CLASS 2

CLASS 1 CLASS 1 CLASS 1

CLASS 1 CLASS 1 CLASS 1 CLASS E

CLASS E

CLASS E

CLASS E

CLASS E

2

Quad

75

B

-

-

CLASS 1 CLASS 1 CLASS 1

CLASS 1 CLASS 1 CLASS 1 CLASS E

CLASS E

CLASS E

CLASS E

CLASS E

3

Double

75

A

CLASS 2

CLASS 2

CLASS 1 CLASS 1 CLASS 1

CLASS 1 CLASS 1 CLASS 1 CLASS E

CLASS E

CLASS E

CLASS E

CLASS E

4

Double

75

B

-

-

CLASS 1 CLASS 1 CLASS 1

CLASS 1 CLASS 1 CLASS 1 CLASS E

CLASS E

CLASS E

CLASS E

CLASS E

5

Fast Double

130

A

CLASS 2

CLASS 2

-

-

-

-

-

-

-

-

-

-

-

6

Fast Double

130

B

-

-

-

-

-

-

-

-

-

-

-

-

-

7

Slow Quad

65

A

CLASS 2

CLASS 2

CLASS 1 CLASS 1 CLASS 1 CLASS 1 CLASS 1 CLASS 1 CLASS E

CLASS E

CLASS E

CLASS E

CLASS E

8

Slow Quad

65

B

-

-

CLASS 1 CLASS 1 CLASS 1 CLASS 1 CLASS 1 CLASS 1 CLASS E

CLASS E

CLASS E

CLASS E

CLASS E

9

Slow Double

65

A

CLASS 2

CLASS 2

CLASS 1 CLASS 1 CLASS 1 CLASS 1 CLASS 1 CLASS 1 CLASS E

CLASS E

CLASS E

CLASS E

CLASS E

10

Slow Double

65

B

-

-

CLASS 1 CLASS 1 CLASS 1 CLASS 1 CLASS 1 CLASS 1 CLASS E

CLASS E

CLASS E

CLASS E

CLASS E

11

Quint-hold

75

A

CLASS 2

CLASS 2

CLASS 1 CLASS 1 CLASS 1 CLASS 1 CLASS 1 CLASS 1 CLASS E

CLASS E

CLASS E

CLASS E

CLASS E

12

Quint-hold

75

B

-

-

CLASS 1 CLASS 1 CLASS 1 CLASS 1 CLASS 1 CLASS 1 CLASS E

CLASS E

CLASS E

CLASS E

CLASS E

13

Burst

75

A

CLASS 2

CLASS 2

CLASS 1 CLASS 1 CLASS 1 CLASS 1 CLASS 1 CLASS 1

-

-

-

-

-

14

Burst

75

B

-

-

CLASS 1 CLASS 1 CLASS 1 CLASS 1 CLASS 1 CLASS 1

-

-

-

-

-

15

Quad, Alternate 

Side-to Side

150

CLASS 2

CLASS 2

CLASS 1 CLASS 1 CLASS 1 CLASS 1 CLASS 1 CLASS 1

-

-

-

-

-

16

Quad, Diagonal 

Alternate

150

-

-

-

-

-

-

-

-

-

-

-

-

-

17

Double, Alternate 

Side-to-Side

150

CLASS 2

CLASS 2

CLASS 1 CLASS 1 CLASS 1 CLASS 1 CLASS 1 CLASS 1

-

-

-

-

-

18

Double, Diagonal 

Alternate

150

-

-

-

-

-

-

-

-

-

-

-

-

-

19

Quint-hold, Alter-

nate Side-to-Side

150

CLASS 2

CLASS 2

CLASS 1 CLASS 1 CLASS 1 CLASS 1 CLASS 1 CLASS 1

-

-

-

-

-

20

Quint-hold, Diago-

nal Alternate

150

-

-

-

-

-

-

-

-

-

-

-

-

-

21

Fast Rotate

120

CLASS 2

CLASS 2

CLASS 1 CLASS 1 CLASS 1 CLASS 1 CLASS 1 CLASS 1

-

-

-

-

-

22

Rotate/Quad

150/75

-

-

-

-

-

-

-

-

-

-

-

-

-

23

Wave Rotate

70

-

-

-

-

-

-

-

-

-

-

-

-

-

24

Random

-

-

-

-

-

-

-

-

-

-

-

-

-

25

Steady 

-

-

-

-

-

-

-

-

-

-

-

-

-

Summary of Contents for 5580 Series

Page 1: ...s inside the vehicle particularly avoiding areas of potential head impact 6 It is the responsibility of the vehicle operator to ensure during use that all features of this product work correctly In us...

Page 2: ...ot in use Figure 1 Important Disable power before wiring up the Minibar Note Operating the Minibar without the lens installed on this product will result in damage that will not be covered under warra...

Page 3: ...nconnected and insulated Flash Pattern Syncing 1 0 Figure 4 Flash Pattern Chart Tabla de Patrones de Intermitencia Flash Graphique de Motif Sequence Description FPM Phase SAE J845 CA T13 5580A 5580CA...

Page 4: ...s and Limitation of Liability MANUFACTURER S SOLE LIABILITY AND BUYER S EXCLUSIVE REMEDY IN CONTRACT TORT INCLUDING NEGLIGENCE OR UNDER ANY OTHER THEORY AGAINST MANUFACTURER REGARDING THE PRODUCT AND...

Page 5: ...or componentes propios del veh culo es decir ba les o puertas abiertas personas veh culos u otras obstrucciones 7 El uso de este o cualquier otro dispositivo de alerta no garantiza que todos los condu...

Page 6: ...ficie magn tica suave y plana es decir que no sean techos de fibra de vidrio estriados etc Aseg rese de que el im n se mantenga limpio TIRE O ENROLLE LA PESTA A HACIA ARRIBA PARA LIBERAR EL VAC O TIRE...

Page 7: ...egundo Si el contacto entre el cable amarillo y el cable rojo dura m s de un segundo se pasa al patr n de intermitencia anterior El patr n de intermitencia de los modelos de VM se selecciona mediante...

Page 8: ...A MEDIANTE LA PRESENTE SE EXCLUYEN LAS GARANT AS IMPL CITAS DE COMERCIABILIDAD O APTITUD PARA UN PROP SITO EN PARTICULAR QUE NO SE APLICAR N AL PRODUCTO EL NICO Y EXCLUSIVO REMEDIO DEL COMPRADOR CON R...

Page 9: ...doit s assurer que la projection du signal d avertissement n est pas bloqu e par des composants du v hicule p ex coffres ouverts ou portes de compartiment ouvertes des personnes des v hicules ou d aut...

Page 10: ...z ou que vous la retirez pour viter de rayer la peinture du v hicule Apr s sa mise en place la mini barre doit fermement adh rer la surface Si l unit glisse ou se d place facilement l installation n a...

Page 11: ...cigare S lection du mode clignotement C blage Le c blage de la mini barre montage d finitif est tel qu indiqu la figure 6 Tout le c blage doit tre d au moins 18 AWG La ligne positive doit disposer d...

Page 12: ...RESSE OU TACITE LES GARANTIES IMPLICITES DE QUALIT MARCHANDE OU D APTITUDE UN USAGE PARTICULIER SONT EXCLUES ET NE S APPLIQUERONT PAS AU PRODUIT LE SEUL ET UNIQUE RECOURS DE L ACHETEUR CONTRE LE FABRI...

Reviews: