ECA • 10 Mountain View Drive • Shelton, CT 06484 • Phone: 1-800-521-3175 • Fax: 203-924-6687
www.electri-cable.com
9065-0002 RevF
1
Innovat ive Power + Dat a Solut ions
Intercept 2
Installation Sheet
NOTE: DO NOT ATTEMPT TO INSTALL THE INTERCEPT PRIOR TO READING THESE INSTRUCTIONS
Step 1.
Prepare table per instructions on separate sheet. Be sure to retain portion of cut out tabletop if it will become
the finished top of the INTERCEPT 2.
Step 2.
Unpack the INTERCEPT 2, being careful not to damage any part, and check to ensure that no items were
damaged during shipping. Review parts list to be sure all parts are present.
Step 3.
TABLE THICKNESS ADJUSTMENT - The INNER PAN ASSY has four (4) adjustable mounting flanges that
can be set for your specific table thickness between .656” - 1.625”. The flanges come set for the thinnest table.
To change the flanges remove the lock nuts (2 per flange) and move the flanges to the hole that corresponds
with the table thickness that the INTERCEPT 2 will be mounted in.
Tighten the lock nuts; be sure all of the flange tops are at the same height
Step 4.
TABLE CUTOUT MOUNTING - Attach CUTOUT PIECE, from table preparation, to top of MAIN HOUSING.
The 8 pilot holes should line up. From underside of the INNER PAN, insert screws (use magnetic screwdriver)
and secure the CUTOUT PIECE to the MAIN HOUSING.
Inner Pan
Assembly
Screws
Qty 8
Cutout Piece
Main Housing
Table Thickness
1.125” – 1.375”
Table Thickness
.83” – 1.125”
Table Thickness
.656” - .83”
Top of Inner Pan
Flange
Table Thickness
1.375” – 1.625”