background image

E800-DTU Wireless Data Transmission Modem     

                                                                                                       

                          E800-DTU(Z2530-485-27) User Manual

 

Copyright ©2012–2017, Chengdu Ebyte Electronic Technology Co.,Ltd     

 

                                                                                                                                   

2

 

1.3.

 

Characteristics 

No. 

Characteristics 

Description 

Role switching 

The user can use the serial port command to let the device switch between the three types of coordinator, 
router and terminal. 

Automatic networking 

Supports power-on automatic networking. The coordinator automatically builds up the network by power, 
and the terminals and routers automatically search and join the network. 

Network self-healing 

Lost network automatic reconnection function. The network intermediate node is lost, and other networks 
automatically  join  or  maintain  the  original  network.  (The  isolated  node  automatically  joins  the  original 
network, and the non-isolated node maintains the original network.) 
The coordinator is lost and there are non-isolated nodes in the original network. The coordinator can join 
the  network  again  or  the  coordinator  of  the  original  PAN_ID  set  by  the  same  user  can  join  the  original 
network. 

Data retention time 

setting 

In the state of the coordinator and router, the user can set the data storage time and use it in conjunction 
with the terminal in the sleep mode to save the data of the terminal device and send the data to the terminal 
after the terminal wakes up. 
Save up to 3 pieces of data, if it is exceeded, automatically clear the first data! After the data is saved, the 
data heap is automatically cleared. 

Automatic resend 

In  single  broadcast(point  transmission)  mode,  when  the  device  fails  to  send  to  the  next  node,  it 
automatically retransmits every message three times. 

Automatic routing 

The  module  supports  network  routing  function.  Routers  and  coordinators  carry  network  data  routing 
functions, and users can form multi-hop networks. 

Support encryption 

protocol   

The  module  uses  AES  128-bit  encryption  to  change  network  encryption  and  anti-listening.  Users  can 
change  the  network  key  by  themselves,  and  the  devices  with  the  same  network  key  can  communicate 
normally. 

Support Serial Port 

Configuration 

Module built-in serial instructions, users can configure (view) the parameters and functions of the module 
through the serial instructions. 

10 

Multi-type data 
communication 

Supports  all-network  broadcast,  multicast  and  on-demand  (single  broadcast)  functions.  Several 
transmission  methods  are  also  supported  in  broadcast  and  single  broadcast  modes,  please  refer  to  the 
details. 

11 

Multiple working mode 

selection 

It supports three working modes: transparent transmission mode, semi-through mode, protocol mode, and 
user can switch freely. 

12 

Channel change 

Supports  16  channel  changes  from  11  to  26  (2405~2480MHZ),  and  different  channels  correspond  to 
different frequency bands. 

13 

Network PAN_ID change 

Any  switch  of  the  network  PAN_ID,  the  user  can  customize  the  PAN_ID  to  join  the  corresponding 
network or automatically select the PAN_ID to join the network. 

14 

Serial Port Baud Rate 

Change 

The user can set the baud rate up to 1M, default digit is 8 bits, stop bit is 1 bit, no parity bit. 

15 

Short address collection 

The user can find the corresponding short address according to the module MAC address (unique, fixed) 
that has joined the network. 

16 

Instruction format 

switching 

This module supports AT command and HEX command, which are easy to configure. 

17 

Module reset 

The user can reset the module through the serial port command. 

18 

One-click Recovery Baud 

Rate 

This  module supports one-button recovery of baud  rate. This function can be used when the user forgets 
the baud rate. The default baud rate is 115200. 

19 

Restore factory settings 

Users can restore the factory settings of the module through serial port commands. 

1.4.

 

Serial Products 

SN. 

Model Number 

RF Chip 

Frequency 

Hz 

Air Data Rate 

bps 

Power 

dBm 

Interface 

Distance 

km 

Antenna Interface 

E800-DTU 

(Z2530-485-27) 

CC2530 

2.4G 

250K 

27 

RS485 

2.5 

SMA-K 

E800-DTU 

(Z2530-485-20) 

CC2530 

2.4G 

250K 

20 

RS485 

1.0 

SMA-K 

    The E18 modules can communicate with the above model

 

 

Summary of Contents for E800-DTU

Page 1: ...ZigBee Ad Hoc Network Wireless Modem E800 DTU Z2530 485 27 User Manual Chengdu Ebyte Electronic Technology Co Ltd...

Page 2: ...d level gauge 1 2 Features All core components are original imported Compared with the current imported wireless modem it features the most advanced the smallest and has the best price Different trans...

Page 3: ...encryption and anti listening Users can change the network key by themselves and the devices with the same network key can communicate normally 9 Support Serial Port Configuration Module built in seri...

Page 4: ...always on when the power is turned on 3 TX LED Sending indicator Yellow flashing when sending data 4 RX LED Receiving indicator Yellow flashing when receiving data 5 LINK LED Connection indicator Red...

Page 5: ...E800 DTU Wireless Data Transmission Modem E800 DTU Z2530 485 27 User Manual Copyright 2012 2017 Chengdu Ebyte Electronic Technology Co Ltd 4 2 2 Product Size...

Page 6: ...m terminal block See below for details Pin No Definition Function Description 1 VCC Crimp power connector positive 8 28V DC 12V or 24V is recommended 2 GND Crimp power connector positive The negative...

Page 7: ...transmits in a full protocol according to the fixed format of the data transmission On demand broadcast multicast are available Please refer to HEX Data Communication Instructions for details N A Rou...

Page 8: ...k Start 5 1 Use Connection Diagram ZigBee ad hoc network module is simple and easy to use In order to let users be familiar with this products quickly this section will guide users to configure and co...

Page 9: ...oard Open the PC software Zigbee_Setting_V1 1 select the port number set the serial baud rate default 115200 and open the serial port Click Read Parameters to read module parameters Select the node ty...

Page 10: ...opyright 2012 2017 Chengdu Ebyte Electronic Technology Co Ltd 9 Read parameters after the network is built Choose another module and set it as a router or terminal according to the same steps the modu...

Page 11: ...0 485 27 User Manual Copyright 2012 2017 Chengdu Ebyte Electronic Technology Co Ltd 10 2 Communication test Click fixed point networking of coordinator and terminal in the host computer The correspond...

Page 12: ...adcast In order to facilitate user observation this experiment is HEX transmission mode If you do not know the device address please enter the corresponding MAC address and click to get the network ad...

Page 13: ...0 DTU Wireless Data Transmission Modem E800 DTU Z2530 485 27 User Manual Copyright 2012 2017 Chengdu Ebyte Electronic Technology Co Ltd 12 Terminal to coordinator Network address Coordinator to termin...

Page 14: ...Transmission Modem E800 DTU Z2530 485 27 User Manual Copyright 2012 2017 Chengdu Ebyte Electronic Technology Co Ltd 13 Terminal to coordinator MAC address Coordinator to terminal Coordinator to termin...

Page 15: ...d format This DTU defaults as the HEX command mode in this mode serial assistant is used to send instructions and enter the temporary AT instruction mode AT command can be used to configure input AT E...

Page 16: ...munication channel Send FE 01 0A FF Return FB channel Send FE 01 0A FF Return FB 0B Read transmitting power Send FE 01 0B FF Return FB txpower Send FE 01 0B FF Return FB 04 Read serial port baud rate...

Page 17: ...FFFE fixed network PAN_ID FFFF stochastic network PAN_ID 6 2 4 Network Keys key 16 bit network key 6 2 5 Network short address ShortAddr 2 Byte address 6 2 6 MAC address Mac_Addr 8 Byte address 6 2 7...

Page 18: ...0F 1000000 6 2 13 Sleep time sleep_time 0 Sleep state is off default Others 1 250 Sleep mode is turned on Sleep_time unit S seconds 6 2 14 Parent node save time time Range 0 120 default 30 Unit S Sec...

Page 19: ...passageway adcx User adc channel comparison table adcx 0 1 2 3 4 5 6 GPIO P0_0 P0_1 P0_2 P0_3 P0_4 P0_5 P0_6 2 adc state value adc_state 0 ADC Enable 1 ADC Turn off 3 adc sample value adc_value 0 0X0C...

Page 20: ...D 1F 10 12 14 16 18 1A 1C 1DF2 EF89 6C 50 09 00 4B 12 0000 0020 39 EA 0A 00 4B 12 00010B040905 device type 02 terminal Network state 01 already existed in network Network PANID 02 F4 PAN_ID 0X02F4 Net...

Page 21: ...number of message in group broadcast Example FC 05 02 01 31 32 33 Example explanation Send HEX data to network group number 1 0X31 0X32 0X33 3 Point broadcast single broadcast data data is the content...

Page 22: ...DE mode return OK CR LF Parameters mode 1 Mode 1 Transparent mode 2 Mode 2 Semi transparent mode 3 Mode 3 Protocol mode Example AT MODE 3 Default MODE 3 6 4 4 AT RMODE Function Query Configure communi...

Page 23: ...ion Query configure network key Format query send AT KEY return KEY key CR LF configure send AT PANID mode return OK CR LF parameters key The network key of 16 Byte Example AT KEY 01030507090B0D0F0002...

Page 24: ...COOR_MAC_ADDR return COOR_MAC_ADDR macaddr CR LF Parameter macaddr 8 Byte MAC address The only IEEE ID Example AT COOR_MAC_ADDR 6 4 12 AT GET_SHORT_ADDR Function Query the short addresses of any MAC...

Page 25: ...ER return CH txpower CR LF configure send AT TXPOWER txpower return OK CR LF Parameter txpower 0 4 transmit power Refer to the power comparison table for details Example AT TXPOWER 4 Default TXPOWER 4...

Page 26: ...AT DATA_TIME return DATA_TIME data_time CR LF configure send AT SLEEP data_time return OK CR LF Parameter data_time 0 120 data save time Unit S Example AT DATA_TIME 30 Default DATA_TIME 30 6 4 19 AT S...

Page 27: ...1AC0 5 0 6 4 23 AT RGPIO_PUT Function Read remote local GPIO input and output mode Format configure send AT RGPIO_PUT addr gpiox return RGPIO_PUT addr input CR LF Parameter addr 0000 FFF8 remote shor...

Page 28: ...and output modes Format Configure send AT PWM addr period duty1 duty2 duty3 duty4 duty5 return OK CR LF Parameters addr 0000 FFF8 remote short address device FFFF local device period Unit 1 62 5ns 0...

Page 29: ...does not know the short address it can search the Short Address in the network through the corresponding instructions according to Mac Address then to carry out point to point communication 6 The coor...

Page 30: ...actical applications Ebyte data Transmitter is suitable for all kinds of point to point point to multipoint wireless data transmission systems such as smart home IoT renovation power load monitoring d...

Page 31: ...ted with a matching antenna or a 50 dummy load otherwise it will easily damage the transmitter if the antenna is connected the distance between the human body and the antenna should preferably exceed...