Ebyte E70-915NW30S User Manual Download Page 25

Chengdu Ebyte Electronic Technology Co.,Ltd

E70-915NW30S User Manual

Copyright ©2012–2019

Chengdu Ebyte Electronic Technology Co.,Ltd

1-24

10. Notes

1. In the sleep mode, the serial baud rate format is 115200, 8N1. If users forget the current baud rate, they can use AT
command to reconfigure in this mode.
2. After the node is associated with the coordinator, the node's information will be saved, and the information still exists
after the node is disconnected from the network. This mechanism has two advantages:

A. When the same node joins the network established by the coordinator, increase the network access speed;
B. After a node enters the network, as long as the current network exists, the short address will never change;

If the coordinator has associated more than 200 devices and wants to continue to associate new devices, it needs to call
the AT + CLINFO command to clear the current network information
3. The average power consumption of a low-power node depends on the wake-up period configured by the user. The
larger the period, the lower the power consumption.
4. Low power consumption nodes cannot receive broadcast data from the coordinator.
5. When using the default parameters, if the node is powered on for more than 60 seconds and has not yet entered the
network, the system reset will be initiated.
6. When the node PANID is set to 0Xffff (65535), the node can join any network, otherwise it will only join the network
with the same PANID.
7. E70 (915NW30S) configure parameters AT + TMCFG = 0 and AT + TMCFG = 1, their modes are long-distance
mode.
8. When using AT + TFICFG = value to set the input transmission format configuration and AT + TFOCFG = value to
set the output transmission format configuration, parameters can be saved without restarting.

11 FAQ

11.1 Communication range is too short

The communication distance will be affected when obstacle exists.

Data lose rate will be affected by temperature, humidity and co-channel interference.

The ground will absorb and reflect wireless radio wave, so the performance will be poor when testing near ground.

Sea water has great ability in absorbing wireless radio wave, so performance will be poor when testing near the sea.

The signal will be affected when the antenna is near metal object or put in a metal case.

Power register was set incorrectly, air data rate is set as too high (the higher the air data rate, the shorter the
distance).

The power supply low voltage under room temperature is lower than 2.5V, the lower the voltage, the lower the
transmitting power.

Due to antenna quality or poor matching between antenna and module.

Summary of Contents for E70-915NW30S

Page 1: ...E70 915NW30S User Manual 915MHz 1W Star Network SMD Wireless Module...

Page 2: ...RMWARE TRANSMITTING MODE 10 5 1 TRANSPARENT TRANSMISSION 10 5 2 SHORT ADDRESS TRANSMISSION 10 5 3 LONG ADDRESS TRANSMISSION 11 6 DEVICE STATUS 11 6 1 AUX DESCRIPTION 11 6 2 LINK DESCRIPTION 12 6 3 ACK...

Page 3: ...Chengdu Ebyte Electronic Technology Co Ltd E70 915NW30S User Manual Copyright 2012 2019 Chengdu Ebyte Electronic Technology Co Ltd 2 REVISION HISTORY 27 ABOUT US 27...

Page 4: ...E70 915NW30S strictly follows design standards of FCC CE CCC and meets various RF certification requirements for exporting Model No Frequency Transmit power Reference distance PCB IPX Package Antenna...

Page 5: ...rature Working humidity Storage temperature E70 915NW30S 24 38 5 mm 4 9 0 1g 40 85 10 90 40 125 C 3 2 Electrical parameters 3 1 1 Transmit current Model No Min Typ Max Unit Remark E70 915NW30S 580 600...

Page 6: ...needs to be processed by the developer through software 3 1 3 Sleep current Product model Min Typ Max Unit Remark E70 915NW30S 1 0 2 0 3 5 A Sleep current usually refers to the current consumed by the...

Page 7: ...dule Although there are many ways to change the communication level it will greatly affect the power consumption of the whole machine 3 2 RF parameters 3 2 1 Transmit power Product model Min Typ Max U...

Page 8: ...different modules After increasing the airspeed of the module the receiving sensitivity will decrease resulting in a decrease in communication distance 3 3 Coverage Product model Min Typ Max Unit Rema...

Page 9: ...d to be floated 8 NC Reserved pin Reserved to be floated 9 NC Reserved pin Reserved to be floated 10 NC Reserved pin Reserved to be floated 11 NC Reserved pin Reserved to be floated 12 NC Reserved pin...

Page 10: ...nd Ground electrode 31 GND Ground Ground electrode 32 ACK Output The user indicates the data transmission result of the module which is pulled down before transmission and pulled up after success It c...

Page 11: ...e is as follows PA_EN LNA_EN Transmitting 1 0 Receiving 0 1 Sleeping 0 0 5 Firmware Transmitting mode 5 1 Transparent transmission Format Values When the coordinator is set to transparent transmission...

Page 12: ...29 64 HEX Null Node C address A4 78 02 46 B5 1C 5A 02 HEX Null Coordinator HEX FF FF FF FF FF FF FF FF AA BB CC Node A address 0A 01 AA 45 65 13 12 44 HEX AA BB CC Node B address 0A 01 AA 45 65 13 12...

Page 13: ...tes when Aux 1 users can transmit data continuously within 128 bytes 2 When AUX 1 it means that all the UART data of the module have been transmitted already Timing Sequence Diagram of AUX when RXD pi...

Page 14: ...er configures the operating mode as 0 the module works in the coordinator mode In the coordinator mode the coordinator can set up the network coordinator is the central node of the network there must...

Page 15: ...g AT command if more than 2 seconds there is no data input the module will close serial port and go to sleep The sleep node is suitable for applications where the user requires high power consumption...

Page 16: ...e and set the serial port parameters default is 115200 8N1 Enter without line breaks to enter the AT command mode When receiving Enter AT Mode the AT mode is successfully entered As shown in Figure 5...

Page 17: ...bit to none the stop bit to 1 bit and the flow control is disabled open the serial port Enter without line breaks to enter the AT command mode When receiving Enter AT Mode the AT mode is successfully...

Page 18: ...leted the DIO11 pin will be set to low level indicating that the network access is successful After waiting for the device to access the network successfully the coordinator enters to AT mode enters t...

Page 19: ...on the serial debugging assistant must be set not to send new lines writing other AT commands must be set to send new lines 2 AT EXIT Exit AT command mode AT EXIT Parameter Description Null Response E...

Page 20: ...tion Get short address and return by UART AT DINFO SELFE Description Get long address and return by UART Example AT DINFO SELFE 6 AT TFOCFG Setting Querying output format configuration can be saved wi...

Page 21: ...s transport mode configuration Response TMCFG 0 AT TMCFG Value Description Value 0 or 1 0 Long Range mode LRM 1 Standard transmission mode GFSK Example AT TMCFG 0 Note The coordinator and node should...

Page 22: ...esponse RSCFG 0 AT RSCFG Value Description Value 0 or 60 65535 S When the value less than 60s the system judges 60 equals 0s does not restart Example AT RSCFG 0 Note This parameter can be used for nod...

Page 23: ...ower parameter Response PWCFG 3 AT PWCFG Value Description Value 0 3 0 Polar Altitude 1 High 2 Medium 3 Low Example AT PWCFG 3 15 AT IOCFG Setting Querying the IO parameter AT IOCFG Description Gets t...

Page 24: ...on when the number of coordinator node devices reaches 50 21 AT TLCFG Setting Querying the concurrency performance parameter reboot valid AT TLCFG Description Gets the concurrency performance paramete...

Page 25: ...f the node is powered on for more than 60 seconds and has not yet entered the network the system reset will be initiated 6 When the node PANID is set to 0Xffff 65535 the node can join any network othe...

Page 26: ...are co channel signal interference nearby please be away from interference sources or modify frequency and channel to avoid interference Poor power supply may cause messy code Make sure that the power...

Page 27: ...Chengdu Ebyte Electronic Technology Co Ltd E70 915NW30S User Manual Copyright 2012 2019 Chengdu Ebyte Electronic Technology Co Ltd 1 26 12 2 Reflow Soldering Curve...

Page 28: ...ription Issued by 1 00 2019 09 18 Initial version huaa 1 10 2019 10 09 content updating Ren About us Technical support support cdebyte com Documents and RF Setting download link www ebyte com Thank yo...

Reviews: