
Chengdu Ebyte Electronic Technology Co.,Ltd
E70-915NW30S User Manual
Copyright ©2012–2019
,
Chengdu Ebyte Electronic Technology Co.,Ltd
1-21
Value: dormant time, per unit second (S). 0~60 S.
Note: When configured as 0, the node will never wake up, that is, the node cannot receive
data but can upload data
Example
:
AT+DMCFG=0
11
AT+RSCFG
Setting/Querying the reboot parameter configuration
(reboot valid)
AT+RSCFG=?
Description:
Gets the reboot parameter configuration
Response
:
RSCFG:0
AT+RSCFG=Value
Description:
Value
:
0 or 60~65535
(
S
)
When the value less than 60s, the system judges 60, equals 0s, does not restart
Example
:
AT+RSCFG=0
Note: This parameter can be used for node disconnection detection. It is recommended to open it.
12
AT+UBCFG
Setting /Querying the baud rate parameter (reboot valid)
AT+UBCFG=?
Description
:
Obtains the baud rate parameter
Response
:
UBCFG:7
AT+UBCFG=Value
Description
:
Value:0~7
0
:
1200
1
:
2400
2
:
4800
3
:
9600
4
:
19200
5
:
38400
6
:
57600
7
:
115200
Example
:
AT+UBCFG=7
13
AT+UPCFG
Setting /Querying the device parity parameter (reboot valid)
AT+UPCFG=?
Description
Gets the device parity parameter
Response
:
UPCFG:0