Chengdu Ebyte Electronic Technology Co,;Ltd
E70-433T14S user manual
Copyright ©2012–2019
,
Chengdu Ebyte Electronic Technology Co,;Ltd
4
Wireless industrial-grade remote control
;
Health care products
;
Advanced Meter Reading Architecture(AMI)
;
Automotive industry applications.
2. Specification and parameter
2.1 Limit parameter
Main parameter
Performance
Min.
Max.
Power supply
(
V
)
0
3.8
Voltage over 3.8V will cause permanent
damage to module
Blocking power
(
dBm
)
-
10
Chances of burn is slim when modules
are used in short distance
Operating temperature
(℃)
-40
85
-
2.2 Operating parameter
Main parameter
Performance
Remark
Min
Typ.
Max.
Operating voltage
(
V
)
2.2
3.3
3.8
≥3.3 V ensures output power
Communication level
(
V
)
-
3.3
-
For 5V TTL, it may be at risk of
burning down
Operating temperature
(℃)
-40
-
85
Industrial design
Operating frequency
(
MHz
)
861
-
876.5
Support ISM band
Power
consumption
Transmitting current [mA]
-
27
-
Instant power consumption
Receiving current [mA]
-
8
-
-
Turn-off current [μA]
-
1
-
Software is shut down
Max Tx power
(
dBm
)
13.6
14.0
15.3
-
Receiving sensitivity
(
dBm
)
-109
-110
-111
Air data rate is 5kbps
Air data rate
(
bps
)
2.5k
2.5k
168k
Controlled via user’s programming
Main parameter
Description
Remark
Distance for reference
1500m
Test condition
:
clear and open area, antenna gain: 5dBi
,
antenna height: 2.5m
,
air data rate: 2.5kbps
TX length
Transmission mode specification
See transmission mode for details