Chengdu Ebyte Electronic Technology Co.,Ltd.
E330-400T13S User Manual
Copyright ©2012–2021
,
Chengdu Ebyte Electronic Technology Co.,Ltd.
14
1: TXD, AUX push-pull output, RXD pull-up
input
0: TXD, AUX open circuit output, RXD open
circuit input -------------------------------------------------
1, 0
Transmitting power (approximate value)
00: 13dBm (default)
01
:
10dBm
10
:
7dBm
11
:
4dBm
consumption.
For example (the meaning of the “SPED” byte of sequence number 3):
The binary bits of the byte
7
6
5
4
3
2
1
0
Specific value (user configuration)
0
0
0
1
1
0
0
0
Representative meaning
Serial port parity 8N1
The serial port baud rate is 9600
The air speed is 1.2k
Corresponding hexadecimal
1
8
7.6 Factory default parameters
Type
Factory default parameter value: C0 00 00 10 52 34
Module model
Frequency
Address
Channel
Air speed
Baud rate
Serial format
Transmit
power
E330-400T13S
433MHz
0x0000
46
2.0Kbps
9600
8N1
13dBm
When the factory settings are restored, the module wake-up time is 1000ms, and the reception will have a delay of about 1.2S
。