background image

Chengdu Ebyte Electronic Technology Co., Ltd.

                                                                                    E22-900M30S User manual

 

Copyright ©2012–2018, Chengdu Ebyte Electronic Technology Co.,Ltd.

                                                                                                                                                                                                       

 

No. 

Name 

Direction 

Function 

GND 

Ground wire, connected to the power reference ground 

GND 

Ground wire, connected to the power reference ground 

GND 

Ground wire, connected to the power reference ground 

GND 

Ground wire, connected to the power reference ground 

GND 

Ground wire, connected to the power reference ground 

RXEN 

Input 

RF switch receiving control pin, connected to external microcontroller IO, 

valid in high level 

TXEN 

Input 

RF switch transmitting control pin, connected to external microcontroller IO   

or DIO2, valid in high level 

DIO2 

Input/Output 

Configurable universal IO port (see SX1262 manual for details) 

VCC 

Power supply, 2.5~5.5V(It is recommended to add external ceramic filter 

capacitor) 

10 

VCC 

Power supply, 2.5~5.5V(It is recommended to add external ceramic filter 

capacitor) 

11 

GND 

Ground wire, connected to the power reference ground 

12 

GND 

Ground wire, connected to the power reference ground 

13 

DIO1 

Input/Output 

Configurable universal IO port (see SX1262 manual for details) 

14 

BUSY 

Output 

For status indication (see SX1262 manual for details) 

15 

NRST 

Input 

Chip reset trigger input pin, valid in low level 

16 

MISO 

Output 

SPI data output pin 

17 

MOSI 

Input 

SPI data output pin 

18 

SCK 

Input 

SPI data output pin 

19 

NSS 

Input 

Module chip select pin for starting an SPI communication 

20 

GND 

Ground wire, connected to the power reference ground 

21 

ANT 

Antenna interface, stamp hole (50 ohm characteristic impedance) 

22 

GND 

Ground wire, connected to the power reference ground 

4.

 

Basic Operation 

4.1

 

Hardware Design 

l

 

It  is  recommended  to  use  DC  stabilized  power  supply  to  supply  power  to  the  module. The  power  supply  ripple 
coefficient is as small as possible, and the module needs to be reliably grounded. 

l

 

Please pay attention to the correct connection of the positive and negative poles of the power supply. If the reverse 
connection is connected, the module may be permanently damaged. 

l

 

Please check the power supply to ensure that between the recommended supply voltage, if exceeding the maximum, 
the module will be permanently damaged. 

l

 

Please check the stability of the power supply, the voltage can not be significantly frequent. 

l

 

When designing the power supply circuit for the module, it is often recommended to reserve more than 30% of the 
margin, and the whole machine is beneficial for long-term stable operation. 

Summary of Contents for E22-900M30S

Page 1: ...E22 900M30S User Manual SX1262 868 915MHz 1W SMD Wireless Module...

Page 2: ...This products obtained FCC CE and RoHS certification already so users do not need to worry about the performance Adopted industrial grade high precision 32MHz crystal the product can cover an ultra w...

Page 3: ...l cause permanent damage to module Blocking power dBm 10 Chances of burn is slim when modules are used in short distance Operating temperature 40 85 2 2 Operating parameter Main parameter Performance...

Page 4: ...or reference 12000m Test condition clear and open area antenna gain 5dBi antenna height 2 5m air data rate 0 3kbps FIFO 256Byte Maximum length of single transmission Crystal frequency 32MHz Modulation...

Page 5: ...s 14 BUSY Output For status indication see SX1262 manual for details 15 NRST Input Chip reset trigger input pin valid in low level 16 MISO Output SPI data output pin 17 MOSI Input SPI data output pin...

Page 6: ...cording to the strength of the interference If necessary appropriate isolation and shielding can be done l If the communication line uses a 5V level a 1k 5 1k resistor must be connected in series not...

Page 7: ...dio wave so the performance will be poor when testing near ground l Sea water has great ability in absorbing wireless radio wave so performance will be poor when testing near the sea l The signal will...

Page 8: ...heck whether there is interference on the SPI line The SPI bus line should not be too long l Unsatisfactory power supply may also cause garbled characters and ensure the reliability of the power suppl...

Page 9: ...wer dBm Test distance km Packaging Size mm Communication Interface E22 900T22S SX1262 868M 915M 22 7 SMD 16 26 UART E22 230T22S SX1262 230M 22 7 SMD 16 26 UART E22 400T22S SX1268 433M 470M 22 7 SMD 16...

Page 10: ...antenna TX433 JW 5 Soft PCB antenna 433M SMA J 2 50mm Flexible Omnidirectional TX433 JWG 7 Soft PCB antenna 433M SMA J 2 5 75mm Flexible Omnidirectional TX433 JK 20 Soft PCB antenna 433M SMA J 3 210m...

Page 11: ...00 2017 10 16 Original version huaa 1 10 2018 5 23 Content added huaa 1 20 2018 9 18 Model No split huaa About us Technical support support cdebyte com Documents and RF Setting download link www ebyt...

Reviews: