Chengdu Ebyte Electronic Technology Co.,Ltd.
Co
pyright ©2012–2021,Chengdu Ebyte Electronic Technology Co.,Ltd.
24
The ADDH\ADDL of relay 2 are 33 and 05 respectively .
So relay 2 can forward the data of relay 1 to network NETID : 05 .
Thus node 3 and node 4 can receive node 1 data. Node 4 outputs data normally, and node 3 has a different address from
node 1 , so no data is output.
③
Two -way relay
Configure as shown in the figure: the data sent by node 1 can be received by nodes 2 and 4 , and the data sent by nodes 2
and 4 can also be received by node 1
.
9 PC Configuration Instructions
The figure below shows the display interface of the host computer for E22 series products. Users can switch to the
command mode through M0 and M1 , and quickly configure and read parameters on the host computer.
the configuration of the host computer, the module address, frequency channel, network ID , and key are all in
decimal display mode; the value range of each parameter:
Network address: 0 ~ 65535