background image

Chengdu Ebyte Electronic Technology Co., Ltd

E21-400G37 User Manual

Copyright ©2012–2019, hengdu Ebyte Electronic Technology Co., Ltd

6

Chapter 3 Mechanical Dimensions and Pin Definitions

PIN

Name

Direction

Usage

1

GND

Ground wire, connected to reference ground

2

+7.5V

PA drive power VCC1

3

+7.5V

PA drive power VCC1

4

GND

Ground wire, connected to reference ground

5

+5V

Control power supply VCC2

6

GND

Ground wire, connected to reference ground

7

TXEN

Input

Enable the transmission mode, effective at high level

(support 3.3V/5V level)

8

RXEN

Input

Receive mode enable, active at high level (support

3.3V/5V level)

9

GND

Ground wire, connected to reference ground

10

PIN

Input/Output

Transmission mode: RF signal input/reception mode: RF

signal output

11

POUT

Output/Input

Transmission mode: RF signal output/reception mode: RF

signal input

12

GND

Ground wire, connected to reference ground

13

GND

Ground wire, connected to reference ground

14

GND

Ground wire, connected to reference ground

15

GND

Ground wire, connected to reference ground

16

GND

Ground wire, connected to reference ground

17

GND

Bottom heat dissipation pad, connecting module GND

Summary of Contents for E21-400G37S

Page 1: ...E21 400G37S User Manual ISM band 433 470MHz patch type PA LNA amplifier module...

Page 2: ...c curve 4 Chapter 3 Mechanical Dimensions and Pin Definitions 6 Chapter 4 Basic Operation 7 4 1 Hardware design 7 4 2 Software Edit 8 Chapter 5 Basic Application 8 5 1 Basic circuit 8 Chapter 6 FAQ 9...

Page 3: ...el or otherwise The test data obtained in this paper are all from the test of the Yibaite laboratory and the actual results may be slightly different It is hereby declared that all trade names tradema...

Page 4: ...for receiving and transmitting control switching SOP chip design mode ultra small size very easy to embed the entire scheme is designed according to industrial grade and the back is large area of bar...

Page 5: ...4 7 5 7 6 7 5V is recommended to ensure the best performance Operating temperature 40 25 85 Industrial grade design Operating frequency band MHz 410 493 ISM band Power waste Emission current mA 1400...

Page 6: ...Chengdu Ebyte Electronic Technology Co Ltd E21 400G37 User Manual Copyright 2012 2019 hengdu Ebyte Electronic Technology Co Ltd 5 2 3 1 Power 2 3 2 Smith and SWR...

Page 7: ...ransmission mode effective at high level support 3 3V 5V level 8 RXEN Input Receive mode enable active at high level support 3 3V 5V level 9 GND Ground wire connected to reference ground 10 PIN Input...

Page 8: ...dule If it is really necessary to pass under the module suppose that the module is welded on the Top Layer and the top layer of the module contact part is paved with copper all are paved with copper a...

Page 9: ...and low level select mode support 3 3 5V level L L Sleep mode When the module enters the sleep mode PA and LNA do not work L H Receiving mode When the module enters the receiving mode PA does not work...

Page 10: ...the module is poor or the quality of the antenna itself is poor 6 2 Modules are easily damaged Please check the power supply to ensure that it is between the recommended power supply voltages If it ex...

Page 11: ...90 sec Peak temperature Tp Peak temperature 220 235 230 250 Aveage ramp down rate Tp to Tsmax Average falling rate 6 second max 6 second max Time 25 to peak temperature Time from 25 to peak temperatur...

Page 12: ...cellent performance and reasonable price Model Type Frequency Gain Size Feeder Interface Feature MHz dBi cm cm TX433 XP 200 Sucker 400 470 4 1 9 200 SMA J Ultra short straight omnidirectional antenna...

Page 13: ...ethod Revision History Version Revision date Description Maintainer 1 0 2021 8 31 First published LJ 1 1 2022 10 12 Parameter confirmation Yan About us Hotline 4000 330 990 Telephone 028 61399028 Supp...