Chengdu Ebyte Electronic Technology Co.,Ltd.
E180-ZG120B User Manual
Copyright ©2012–2020, Chengdu Ebyte Electronic Technology Co.,Ltd.
20
external MCU serial port
in wireless receiving state
Read UART wake up
keep time
36
Send
:
FE 01 36 FF
Return
:
FB 36 Uart_holdtime
Send
:
FE 01 36 FF
Return
:
FB 36 64
Read port info.
37
Send
:
FE 05 37 FF
Return
:
FB 37 Endpoint_info
Send
:
FE 05 37 FF
Return
:
FB 37 01 FE B0
05 04
Read link key of trust
center
38
Send
:
FE 10 38 FF
Return
:
FB 10 TrustCentLinkKey
Send
:
FE 10 38 FF
Return
:
FB 38
5A 69 67 42 65 65 41 6C
6C 69 61 6E 63 65 30 39
6.5.3
Configuration instruction set
Configure device type
Send
:
FD 01 01 dev_type FF
Return
:
FA 01
Send
:
FD 01 01 03 FF
Return
:
FA 01
Configure PAN_ID
Send
:
FD 02 03 pan_id FF
Return
:
FA 03
Send
:
FD 02 03 FE 5B FF
Return
:
FA 03
Configure the network
group number
Send
:
FD 01 09 group FF
Return
:
FA 09
Send
:
FD 01 09 01 FF
Return
:
FA 09
Configuring
communication channel
Send
:
FD 01 0A channel FF
Return
:
FA 0A
Send
:
FD 01 0A 0B FF
Return
:
FA 0A
Configure transmit power
Send
:
FD 01 0B txpower FF
Return
:
FA 0B
Send
:
FD 01 0B 0A FF
Return
:
FA 0B
Configure serial port baud rate
Send
:
FD 01 0C baud FF
Return
:
FA 0C
Send
:
FD 01 0C 09 FF
Return
:
FA 0C
Configure sleep time
(end-device valid)
Send
:
FD 01 0D sleep_time FF
Return
:
FA 0D
Send
:
FD 01 0D 54 FF
Return
:
FA 0D
Configure the target
network short address
Send
:
FD 02 23 dec_addr FF
Return
:
FA 23
Send
:
FD 02 23 00 00 FF
Return
:
FA 23
Configure the target
network group number
Send
:
FD 01 24 netid FF
Return
:
FA 24
Send
:
FD 01 24 00 FF
Return
:
FA 24
Configure target long
address
Send
:
FD 08 25 dec_mac FF
Return
:
FA 25
Send
:
FD 08 25 0A 1C 21
FE FF 57 B4 14 FF
Return
:
FA 25
Configure system send
mode
Send
:
FD 01 26 mode FF
Return
:
FA 26
Send
:
FD 01 26 02 FF
Return
:
FA 26
Configure the data output
mode
Send
:
FD 01 27 mode FF
Return
:
FA 27
Send
:
FD 01 27 00 FF
Return
:
FA 26
Configure to open
centralized network time
Send
:
FD 01 28 time FF
Return
:
FA 28
Send
:
FD 01 28 FF FF
Return
:
FA 28
Configure the period of
rejoin after the end-device
Send
:
FD 01 29 time FF
Return
:
FA 29
Send
:
FD 01 29 05 FF
Return
:
FA 29