Chengdu Ebyte Electronic Technology Co.,Ltd.
E180-ZG120B User Manual
Copyright ©2012–2020, Chengdu Ebyte Electronic Technology Co.,Ltd.
21
node loses the parent node.
The maximum number of
rejoins after the end-device
node loses the parent node
Send
:
FD 01 30 time FF
Return
:
FA 30
Send
:
FD 01 30 05 FF
Return
:
FA 30
Configuring the wireless
remote configuration ID
Send
:
FD 02 31 header FF
Return
:
FA 31
Send
:
FD 02 31 A8 8A FF
Return
:
FA 31
Configure all network
parameters
Send
:
FD 1A FE all_info FF
Return
:
FA FE
Send
:
FD 1A FE 03 FE 5B
01 0B 0A 09 54 00 00 00 0A
1C 21 FE FF 57 B4 14 02 00
FF 05 05 A8 8A FF
Return
:
FA FE
Configure Remote/Local
GPIO Input and Output
Status
Send
:
FD 03 20 GpioId In/Out level FF
Return
:
FA 20
Send
:
FD 03 20 00 01 01 FF
Return
:
FA 20
Configure remote/local
PWM status
指令:
FD 06 21 PwmId start/stop
Period1 Period2 duty1 duty2 FF
Return
:
FA 21
Send
:
FD 06 21 00 FF 03 65
02 48 FF
Return
:
FA 21
Device restart
Send
:
FD 00 12 FF
Return
:
FA 12
Send
:
FD 01 12 FF
Return
:
FA 12
Restore factory settings
Send
:
FD 00 13 FF
Return
:
FA 13
Send
:
FD 01 13 FF
Return
:
FA 13
Read the delayed printing time
of AUX wake up external
MCU serial port in wireless
receiving state
Send
:
FD 01 35 AUX_delaytime FF
Return
:
FA 35
Send
:
FD 01 35 04 FF
Return
:
FA 35
Read UART wake up keep
time
Send
:
FD 01 36 Uart_holdtime FF
Return
:
FA 36
Send
:
FD 01 36 64 FF
Return
:
FA 36
Read port info.
Send
:
FD 05 37 Endpoint_info FF
Return
:
FA 37
Send
:
FD 05 37 01 FE B0
05 04 FF
Return
:
FA 37
Read link key of trust center
Send
:
FD 10 38 TrustCentLinkKey FF
Return
:
FA 38
Send
:
FD 10 38
5A 69 67 42 65 65 41 6C
6C 69 61 6E 63 65 30 39
FF
Return
:
FA 38
6.5.4 Network operation instruction set
Open network
Send
:
F5 01 40 01 FF
Return
:
FC 40 00
Send
:
F5 01 40 01 FF
Return
:
FC 40 00
Leave Network
Send
:
F5 01 40 02 FF
Return
:
FC 40 00
Send
:
F5 01 40 02 FF
Return
:
FC 40 00
Create network
Send
:
F5 01 40 03 FF
Return
:
FC 40 00
Send
:
F5 01 40 03 FF
Return
:
FC 40 00