Chengdu Ebyte Electronic Technology Co.,Ltd
Copyright ©2012–2019
,
Chengdu Ebyte Electronic Technology Co., Ltd.
4-14
5
Data + RSSI;
Data + short a RSSI;
Data + long a RSSI;
Transmit
power
Read/Write
-37dbm
~
7dbm
Module output power: high power consumption
requirements, where the distance is not required,
the transmission power can be reduced to save
average power consumption;
Remote
configuratio
n ID
Read/Write
2 byte
A8 8A
;
It is used to determine whether the data received
by the air in the air is a remote configuration command.
Customers can change the unlimited configuration ID
according to the requirements. The default is A8 8A;
Local
network
group
number
Read/Write
0
~
255
Used to configure the group number of the device in
network;
Target
network
group
number
Read/Write
0
~
255
Group number corresponding to the target when
configuring device multicast;
Wake-up
period
(sleep time)
Read/Write
0
~
2010s
It is used to configure the wake-up period of the
end-device sleep device. The larger the period is, the
lower the overall power consumption is, but the greater
the delay of receiving data is;
Lost parent
node
reconnectio
n period
Read/Write
1
~
255 minutes
When the parent node is lost (the coordinator is powered
down), the end-device reconnects the previous network
at regular intervals;
Maximum
times of
reconnectio
ns
Read/Write
1
~
255 times
After the parent node is lost, the maximum times of
reconnections, if it has not been reconnected
successfully, clears the previous network information,
rescans the new network, and the scanning period is
equal to the reconnection period;
IO status
Read/Write
High/Low
Access/control module level status of the GPIO channel;
PWM
Read/Write
1
~
500ms
Access/control module duty cycle and period of the
PWM channel;
ADC value
Read
0
~
3300mv
Read the ADC value of the device, where 0 channel can
read the device power voltage value;