Chengdu Ebyte Electronic Technology Co.,Ltd.
E180-DTU(Z20-ETH) User Manual
Copyright ©2012–2023,Chengdu Ebyte Electronic Technology
Co.,Ltd.
Technology Co., LTD
60
(2) Click "Start distribution network", and the LINK light of DTU equipment flashes quickly at 10Hz. At this time, ensure that
the coordinator equipment is also in the distribution network state (see Section 5.1). Wait for a while, the LINK light of DTU
becomes long light or 1Hz flashing (router mode). Click "Read parameters" to view the network access information of the
device. At this time, the network status is "connect". If the LINK light is out and the network state is "not have", the module
network fails, check whether the coordinator device is in the distribution state and the distance between the coordinator device
and the router / terminal device is within a reasonable range.
(3) View the router / terminal device information, including the MAC address and the short address. Click the "Device staging
list" on the computer interface of the coordinator device to view the 9 byte SN number of the access device (Note: there may be
multiple SN numbers in a module, each SN number represents one peripheral or function, the more the module function, the
more SN number), SN number can be used to control the device and the device binding transtransmission target.
(4) On the upper computer interface of the coordinator device, click "Device Control Instruction" and click "Refresh the device
Summary of Contents for E180-DTU(Z20-ETH)
Page 1: ...E180 DTU Z20 ETH ...