Chengdu Ebyte Electronic Technology Co.,Ltd.
E180-DTU(Z20-ETH) User Manual
Copyright ©2012–2023,Chengdu Ebyte Electronic Technology
Co.,Ltd.
Technology Co., LTD
58
Combined with the upper computer software to quickly and simply build a ZigBee network, the specific steps are as
follows:
(1) Connect radio 1 to the computer, open the upper computer software "ZigBee3.0 upper computer", select the device type,
input the IP address, input the port number, click the connect server, and see the right window.
(2) the module factory is HEX instruction configuration mode, E180-DTU if in AT command mode, need to switch to HEX
instruction mode, click "read parameter", message box prompt "read parameter success", the main network parameters include:
long address, station type default coordinator (if not please set to coordinator), network status is "not have" (if it is not necessary
to exit the network or restore the factory). If the read parameter is invalid, it is possible that the module is currently in
transmission mode and needs to click "Enter the Configuration Mode", and the message box prompts "Enter the configuration
state successfully".