Copyright ©2012–2019
,成都亿佰特电子科技有限公司
23
Inquire
AT+DATDLY?
+OK=[para]
Set
AT+DATDLY=[para]
+OK
:
success
+ERR=[NUM]
:
error
parameter
para
(
ASCII
)
description
0
shut down
1
On (default)
Description
Take effect immediately, save when power off;
Turn on the output delay, the maximum data packet does not exceed 244 bytes;
Turn on the output delay, and the air packet input is too fast, which will cause the entire packet to be
lost.
6.4.14 AT+MAC Local MAC Address
Command
Response
Inquire
AT+MAC?
+OK=[para]
parameter
para (HEX): MAC address
Example: F0E1D2C3B4A5
Description
Take effect immediately, save when power off.
Sample
Command: AT+MAC?
Return: 2B 4F 4B 3D FE 30 EE 50 35 DA
Explanation: The local MAC address is FE 30 EE 50 35 DA
6.4.15 AT+PEERMAC Connected Device MAC
Command
Response
Inquire
AT+PEERMAC?
+OK
:
success
+ERR=[NUM]
:
error
parameter
MAC
(
HEX
)
:MAC address;
Description
Take effect immediately.