6. AT Command
Note: Before sending operation instructions, first ensure that the module is in wake-up mode, otherwise it will not be able
to receive configuration instructions.
6.1 Instructions
All AT commands and responses do not need to add carriage return (\r), line feed (\n)
Command error response ERR=[NUM].
(NUM is ASCII)
AT command parameter format: [para]. Does not contain [].
6.2 Error code
NUM
Description
Cause of error
Solution
1
unknown error
2
Invalid parameter
1
、
Parameter out of range;
2
、
Wrong number of parameters;
Check parameters
3
Number parameter length
1
、
Field string type, HEX group number
type has read over the maximum or
under the minimum length limit
Check the parameter length against
the command
4
Parameter is empty
Check parameters
5
busy
1.Parsing instructions;
Resend the instruction later
6
role
1.The current role does not support this
operation.
Confirm the current role of the module
7
not connected
1.The current device is not connected
and this operation is not supported.
300
MAC address not found
301
MAC binding list is full
Mac binding can bind 8-bit address at
most.
Delete the invalid address and add it
again.
Summary of Contents for E104-BT5011A
Page 1: ...E104 BT5011A User Manual V1 0 RF52811 BLE5 1 Low Power BLE to Serial Module...
Page 5: ...Copyright 2012 2019 IV 14 ABOUT US 44...
Page 44: ...Copyright 2012 2019 39 10 2 Reflow Soldering Curve Chart 10 2 Reflow soldering curve...
Page 47: ...Copyright 2012 2019 42 transmissio n Chart 11 1 Related model list...
Page 48: ...Copyright 2012 2019 43 12 Package for bulk order Chart 12 1 Packaging Chart...