14
01
:
128000
02
:
115200
03
:
76800
04
:
57600
05
:
19200
06
:
9600
07
:
4800
Note
:
This instruction be suitable for operation of e104-BT112-L and e104-BT12SP-N
Example: 03 C0 0E 02
,
Modification successfully returns 03400E02 if parameter is out of range
returns 034000010D
4.2.1.3 Baud read
Operational code
Parameter
Request
0x02
None
Respond
0x02
Returns the serial number of the set baud rate
Example
Order
Return
Explanation
02 C0 02
03 40 02 xx
xx represents the baud
rate
number
00
:
230400
01
:
128000
02
:
115200
03
:
76800
04
:
57600
05
:
19200
06
:
9600
07
:
4800
Note:
This instruction is applicable to E104-BT12SP-L and E104-BT12SP-N configuration operation.
4.2.1.4 Power Settings
Operational code
Parameter
Request
0x03
Power number to be set (range 0x00~0x0C)
Respond
0x03
Return to the set power number
Example
Order
Explanation
03 C0 03 xx
Xx represents the baud rate label to be set
(
0x00~0x0A
)
00
:
+10dBm
01
:
+8dBm
02
:
+6dBm
03
:
+4dBm