background image

Chengdu Ebyte Electronic Technology Co., Ltd.

E78-900M22S

User manual

Copyright ©2012–2021

Chengdu Ebyte Electronic Technology Co.,Ltd.

1

E104-BT12LSP User Manual

TLSR8253F512 Serial Patch SIG Mesh Group Module

Summary of Contents for E104-BT12LSP

Page 1: ...engdu Ebyte Electronic Technology Co Ltd E78 900M22S User manual Copyright 2012 2021 Chengdu Ebyte Electronic Technology Co Ltd 1 E104 BT12LSP User Manual TLSR8253F512 Serial Patch SIG Mesh Group Modu...

Page 2: ...2 BASIC CIRCUIT 8 4 FUNCTIONAL INTRODUCTION 9 4 1 BASIC CONCEPT 10 4 2 DATA FORMAT 12 5 SWITCH DIO 20 5 1 USE OF SWITCHES 21 6 QUICK GET START 21 6 1 RESTORE FACTORY SETTINGS RESTORE 21 6 2 EQUIPMENT...

Page 3: ...ed is given including but not limited with respect to the accuracy correctness reliability and fitness for a particular purpose of the information This document may be revised by EBYTE at any time For...

Page 4: ...tion L Lightness model one key implementation of lamp control application scene and support Skycat elves Suitable for Internet of Things information gathering large scale network communication smart h...

Page 5: ...p Max Voltage supply V 1 9 3 3 3 6 3 3 V ensures output power Communication level V 3 3 For 5V TTL it may be at risk of burning down Operating temperature 40 85 Frequency MHz 2400 2483 5 ISM band Powe...

Page 6: ...inition No Pin item Pin direction Application 1 GND Ground wire connect to the power reference ground 2 PWM1 PWM Output Green light corresponding to SIGMESH HSL 3 PWM2 PWM Output Red light correspondi...

Page 7: ...e occurs between recommended supply voltages if exceeded Please check the stability of the power supply The voltage cannot fluctuate significantly and frequently Please check the stability of the powe...

Page 8: ...ormance Keep away from the 2 4 GHz TTL protocol in some physical layers e g USB 3 0 The module must not be mounted inside the metal housing which will greatly weaken the transmission distance 3 2 Basi...

Page 9: ...M C E 70M B D 70M Interpreting the simulation application scene above The distance from Module A to Module C is 70 meters beyond 50 meters of our module s transmission distance so module A cannot send...

Page 10: ...ll be there The following link reaches module E where A sends data to B B to C C to D D to E 4 1 Basic Concept 4 1 1 NetKey Network keys are used to protect network layer communications is a key gener...

Page 11: ...sion package contains APP related SDKs for customer development A single device supports only one role In the EBYTE scheme our modules support three roles provision node and mesh node LPN node which i...

Page 12: ...Unicast Element An address corresponds to an element from the Model introduction above We can call it an elemental address It is the unique address assigned to a Node node by a PROVISION device during...

Page 13: ...instruction 4 2 1 1 Get the current network address and status of the device Network keys are used for network IDs assigned by provisers during network formation in the following format Operation al...

Page 14: ...code Parameter Request 0x02 None Respond 0x02 Returns the serial number of the set baud rate Example Order Return Explanation 02 C0 02 03 40 02 xx xx represents the baud rate number 00 230400 01 12800...

Page 15: ...l code Parameter Request 0x04 None Respond 0x04 Returns the serial number of the power currently in use Example Order Return Explanation 02 C0 04 03 40 04 xx xx represents power number 00 10dBm 01 8dB...

Page 16: ...licable to E104 BT12SP L and E104 BT12SP N configuration operation Status value 00 indicates success 4 2 1 8 MAC Read Operation al code Parameter Request 0x07 None Respond 0x07 Returns the device s cu...

Page 17: ...ad to Ali and Set Up Device Information document 4 2 1 12 Set LPN to Time Out and Return to Sleep Operation al code Parameter Request 0x0B None Respond 0x0B Set time out sleepout Example Request 04 C0...

Page 18: ...IME 16 cimal segment mode Column Set 5000 ms convert 5000 to 16 digit value 1388 When you set it you need to write 8813 04 C0 0D 8813 4 2 1 15 Reading LPN polling friend time Operation al code Paramet...

Page 19: ...8813 8813 is small end mode the actual value is 1388 converted to decimal value is 5000 4 2 2 SIG Messages The E104 BT12 module supports SIG Generic and Lighting HSL model control see Mesh Profile an...

Page 20: ...time to less than 8 bytes the data format is as follows Send Order 1byte Target address 2 bytes Data 0xC2 Primary address of Target device Valid data Receive Order 1byte Target address 2 bytes Origin...

Page 21: ...h function Then B device element is then assigned to C002 and C device to C003 If the two switches DIO1 through device A are connected high then device B lights up DIO If one is low then device B ligh...

Page 22: ...have Ali triad information before use See Documentation Apply Triad to Ali and Set Up Device Information 6 2 1 Using Tmallgenie in the Internet Voice enters the net directs the voice command Tmallgen...

Page 23: ...byte Electronic Technology Co Ltd 23 See the Tutorial on Use of Tutorials for details 6 2 3 Mobile phone APP access and control devices 6 2 3 1 Access to the network 1 Open the APP and click this plus...

Page 24: ...Chengdu Ebyte Electronic Technology Co Ltd E104 BT12LSP User Manual Copyright 2012 2021 Chengdu Ebyte Electronic Technology Co Ltd 24...

Page 25: ...g in the previous step returns to the APP home page you can see a lamp click on the lamp and see that the device s LED is switching on and off according to your operation 4 When you press the length o...

Page 26: ...ual Copyright 2012 2021 Chengdu Ebyte Electronic Technology Co Ltd 26 6 2 3 2 Publishing and Subscribing Grouping 1 Pressing multiple devices in turn into GROUP and then ticking the options on this pa...

Page 27: ...onic Technology Co Ltd E104 BT12LSP User Manual Copyright 2012 2021 Chengdu Ebyte Electronic Technology Co Ltd 27 2 When grouping is successful group control can be carried out through GROUP on the mo...

Page 28: ...uipment If the Target address is the group address the device in the current group will respond See Mesh Model 3 2 1 2 Generic OnOff Set for more information E104 BT12SP sends the light off command ge...

Page 29: ...addresses Device 0002 broadcasts hexadecimal data for 8202000 Writing the Target address as FFFF is broadcasting where all devices including their own receive data Sender 09 C2 ffff 8202 01 00 00 00...

Page 30: ...chnology Co Ltd 30 6 4 2 Group address transmission data For example Device 0002 sends hexadecimal data for 82 0200 000 to this group of device C001 Sender 09 C2 0004 8202 01 00 00 00 Receiver 0C 42 0...

Page 31: ...address to transmit data to an LPN For example e8 ff 00 00 00 00 02 01 02 00 80 1b 02 00 01 c0 18 0A 00 00 e8 ff 00 00 00 00 02 01 02 00 80 1b 02 00 01 c0 180A 00 00 Cmd fixed field fix fix Target add...

Page 32: ...error rate is too high There is interference from the same frequency signal nearby away from the source of interference or from modifying frequency and channel The clock waveforms on the UART are not...

Page 33: ...Chengdu Ebyte Electronic Technology Co Ltd E104 BT12LSP User Manual Copyright 2012 2021 Chengdu Ebyte Electronic Technology Co Ltd 33 8 2 Backflow Welding Curve...

Page 34: ...Description Issued by 1 0 2021 04 14 Initial version About us Technical support support cdebyte com Documents and RF Setting download link www ebyte com Thank you for using Ebyte products Please cont...

Reviews: