![Ebyte E104-BT10-IPX User Manual Download Page 22](http://html1.mh-extra.com/html/ebyte/e104-bt10-ipx/e104-bt10-ipx_user-manual_3847569022.webp)
Chengdu Ebyte Electronic Technology Co., Ltd
E104-BT10-IPX User Manual
Copyright ©2012–2019
,
C
hengdu Ebyte Electronic Technology Co., Ltd
4-21
21. Query whether enter sleep and timeout for entering sleep
Operation
code
Parameter
Request
0x18
/
Respond
0x18
Query whether E104-BT10N-IPX enter sleep and timeout
for entering sleep
For example
Request
:
02 c0 18
Respond
:
03 40 18 05
Notes
:
1
、
Suitable for E104-BT10N-IPX
2
、
Query parameter 05 for the sleep timeout after the serial port stops working
,
unit : S, range: 0X01-0XFF
,
4.3.2 SIG Message
E104-BT10 supports SIG generic model and Lighting HSL model control ( refer to Mesh Profile and Mesh
Model for details about SIG message).SIG message follows format below
:
Transmitting
Command
(
1 byte
)
Target address
(
2 byte
)
Sig mesh message
0xC1
Main address of target
device
Request
Receiving
Command
(
1 byte
)
Target address
(
2 byte
)
Original address
(
2
byte
)
Sig mesh
message
0x41
Main address of target
device
Main address of
original device
Respond
For example
:
1
、
Generic onoff control
:
Control device with main address 0004, outputting high
level without latency
Request
09
C1
0004 8202
01
000000
Respond
08
41
0004 0001 8204
01
Control device with main address 0004, outputting low
level without latency
Request
09
C1
0004 8202
00
000000
Respond
08
41
0004 0001 8204
00
2
、
Delete node control
:
Remove nodes with main address 0004 out of current network
(
E104-BT10G-IPX starts control
)
Request
09
C1
0004 8202 01000000
Respond
08
41
0004 0001 8204 00