![Ebyte E104-BT10-IPX User Manual Download Page 17](http://html1.mh-extra.com/html/ebyte/e104-bt10-ipx/e104-bt10-ipx_user-manual_3847569017.webp)
Chengdu Ebyte Electronic Technology Co., Ltd
E104-BT10-IPX User Manual
Copyright ©2012–2019
,
C
hengdu Ebyte Electronic Technology Co., Ltd
4-16
7.Networking filter configuration
Operation
code
Parameter
Request
0x06
Serial MAC address of allowed device
Respond
0x06
MAC address of allowed device
For
example
Request
:
09 C0 06 00 112233445566
Respond
:
33 40 06 01 112233445566 00…00
(
00...00 means space for
unbound MAC
)
Notes
:
1
、
Suitable for
E104-BT10G-IPX
2
、
Return started serial number and joined MAC
8.To delete networking filter
Operation
code
Parameter
Request
0x07
Serial number to be deleted
(
1 byte
)
Respond
0x07
Serial MAC address of deleted device
For
example
Request
:
03 C0 07 00
Respond
:
33 40 07 00 1234567890AB 00…00
(
00...00 means space for
unbound MAC
)
Notes
:
1
、
Suitable for E104-BT10G-IPX
2
、
Return deleted serial number and MAC
9.To read networking filter
Operation
code
Parameter
Request
0x08
/
Respond
0x08
Return started serial number and joined MAC
For
example
Request
:
02 C0 08
Respond
:
33 40 08 01 112233445566 00…00
,
00…00
(
means space for
unbound MAC
)
Notes
:
1
、
Suitable for E104-BT10G-IPX
1
、
Return started serial number and MAC
10.Device enters network
Operation
Parameter