Chengdu Ebyte Electronic Technology Co.,Ltd.
E103-W07 User Manual
Copyright ©2012–2021
,
Chengdu Ebyte Electronic Technology Co.,Ltd.
19
Inquire
AT+MEID?
+MEID:["mesh id"]
Set up
AT+ MEID = ["mesh id"]
+OK success
+ERR:[NUM] error
parameter
mesh id
The identity of the Mesh network. It consists of 6 bytes.
XX:XX:XX:XX:XX:XX
Description
1.
Restart to take effect, save when power off
2.
Default value: "00:00:00:00:00:01"
3.
MESH ID is the MESH network identification. Modules with different MESH IDs cannot join the
same network.
Example
Get the mesh ID:
AT+MEID?
Module response:
+MEID: "00:00:00:00:00:01"
AT+MEID=”00:00:00:00:00:22"
5.5.3 AT+MEAP mesh network ap information
Instruction
Answer
Inquiry
AT+MEAP?
+MEAP:[“ password”]
Setting
AT+ MEAP = [“password“]
+OK
Success
+ERR:[NUM]
Error
Parameter
password
Password is a character string, its length range: 8~63 bytes
Description
1. Restart to take effect, save when power off
2. Default: 12345678;
3. In the same network, the password must be the same, otherwise you cannot join;
Example
Get mesh ap information:
AT+MEAP?
Module response:
+MEAP:"12345678"
AT+MEAP=”11111111"
5.5.4 AT+MECHANNEL MESH network channel
Instruction
Answer
Inquiry
AT+MECHANNEL?
+ MECHANNEL:=[channel],[channel switch]
Setting
AT+MECHANNEL=[channel],[channel switch]
+OK
Success
+ERR:[NUM]
Error
Parameter
channel
MESH network channel. Value range 1 ~ 14. The default
is 1
channel switch
0(default)
Enable channel switching
1
Prohibit channel switching