background image

Chengdu Ebyte Electronic Technology Co., Ltd.

E03-W05A User Manual

Copyright ©2012–2020

Chengdu Ebyte Electronic Technology Co., Ltd

32

Revision history

Version

Date

Description

Issued by

1.0

2020-6-18

Initial version

Roy

1.1

2020-7-14

Format revision

Li

About us

Technical support:

[email protected]

Documents and RF Setting download link:

www.ebyte.com

Thank you for using Ebyte products! Please contact us with any questions or suggestions: [email protected]

-------------------------------------------------------------------------------------------------

Official hotline:028-61399028

Web:

www.ebyte.com

Address:

B5 Mould Park, 199# Xiqu Ave, High-tech District, Sichuan, China.

Summary of Contents for E103-W05A

Page 1: ...Chengdu Ebyte Electronic Technology Co Ltd E03 W05A User Manual E103 W05A User Manual W600 2 4GHz DIP Cost effective WIFI module ...

Page 2: ...ware writing 8 Chapter 5 Basic Application 9 5 1 Basic circuit 9 5 2 Basic usage 9 Chapter 6 Quick Start 10 6 1 Preparation before configuration 10 6 2 Application of TCP Server under AP 10 6 2 1 Application description 10 6 2 2 Network Model 11 6 2 3 Parameter configuration 11 6 3 The application of the TCP Client module working under STA 16 6 3 1 Application description 16 6 3 2 Network Model 16...

Page 3: ...apter 7 Frequently Asked Questions 26 7 1 Transmission distance is not ideal 26 7 2 Module is easily damaged 26 7 3 Precautions 26 7 3 1 The relationship between AP STA Server Client 26 7 3 2 Note for transparent transmission 27 7 3 2 AP The maximum number of connections connected to the server 27 7 3 2 AT command 28 Chapter 8 Welding Operation Guidance 29 8 1 Reflow temperature 29 8 2 Reflow prof...

Page 4: ...o use and quick to use both for old and new users and is a good data transmission partner in the Internet of Things The E103 W05 module is developed by Chengdu Ebyte Electronic Technology Co Ltd based on the W600 chip of Winner Micro The module integrates transparent transmission function ready to use supports serial AT command set server AT command set users can use the network access function th...

Page 5: ...ation Built in watchdog never crash Parameter memory save when power off 1 3 Application scenarios Wireless meter reading Wireless sensing Smart home Industrial remote control and telemetry Smart buildings High voltage line detection Environmental engineering Highway Small weather station Automated data collection Consumer Electronics Smart robot Street light control ...

Page 6: ...er Main parameter Performance Remark Min Type Max Operating voltage V 3 0 3 3 3 6 3 3V can guarantee output power Communication level V 3 3 3 6 It is recommended that the difference between the supply voltage and the supply voltage is less than 0 3V to reduce power consumption Operating temperature 40 85 Industrial design Operating frequency MHz 2400 2484 802 11 b g n Power consumption Emission cu...

Page 7: ...ption Remark Reference distance 130M Clear and open 2 5 meters high Operating frequency 80MHz Modulation DSSS DBPSK DQPSK CCK and OFDM BPSK QPSK 16QAM 64QAM Package DIP Communication Interface Serial port 600bps 2 0Mbps Dimensions 24 7 14 4 11 2mm 0 2mm PCB onboard antenna DIP RF interface PCB The default PCB antenna the equivalent impedance is about 50Ω Weight 1 20 0 1 Unit g Chapter 3 Size and p...

Page 8: ...ower to the module The power supply ripple factor should be as small as possible and the module should be grounded reliably Please pay attention to the correct connection of the positive and negative poles of the power supply Reverse connection may cause permanent damage to the module Please check the power supply to ensure that it is between the recommended supply voltages If the maximum value is...

Page 9: ...etic interference around the module it will greatly affect the performance of the module According to the intensity of the interference it is recommended to stay away from the module If the situation permits proper isolation and shielding can be done Assuming that there are traces with large electromagnetic interference around the module high frequency digital high frequency analog power wiring it...

Page 10: ... establishes a TCP or UDP server module 2 is set to STATION mode and connected to AP 1 and communicates with module 1 through TCP or UDP Client 1 Module and Server communication The Wi Fi module is connected to the network through a wireless router and communicates with a server on the network LAN or Internet through TCP Client or UDP 2 Module and Client communication If you need to connect to the...

Page 11: ...module first of all the user needs to ensure that the working voltage of the module is 3 0 3 6V typical value is 3 3V the serial port pins have been correctly connected to the relevant serial port tools and can communicate normally 6 1 Preparation before configuration Hardware used in this section 1 E103 W05 Wi Fi module 2 E103 W05 model Wi Fi module test board 3 Office computer 4 1 router can be ...

Page 12: ...e TCP Server of the module and realize the communication process 6 2 2 Network Model 6 2 3 Parameter configuration Open the E103 W01 configuration software select the serial port number and baud rate default 115200 query the version information and check whether there is version related data in the receiving box If there is it means the communication is normal As shown below ...

Page 13: ...Chengdu Ebyte Electronic Technology Co Ltd E03 W05A User Manual Copyright 2012 2020 Chengdu Ebyte Electronic Technology Co Ltd 12 ...

Page 14: ...ectronic Technology Co Ltd 13 Set the working mode of the module to AP and set related AP parameters such as AP name password encryption method channel number etc After the setting is successful we can search through the WIFI in the lower right corner of the computer to find our module and connect it ...

Page 15: ... Copyright 2012 2020 Chengdu Ebyte Electronic Technology Co Ltd 14 When connected the module will print the following information showing the MAC address of the connected STA and the assigned IP address Now we create TCP Server in the module and listen on the port ...

Page 16: ...ctronic Technology Co Ltd 15 We build a client on the PC and connect to the client of the module and then we can send data Here if the server needs to send data to the client we can send it through the AT CIPSEND command Here users can download the AT instruction manual of E103 W05 in the data download ...

Page 17: ...computer is also connected to the same WIFI so that the E103 W05 and the computer are in the same local area network Create a TCP Client on the module side and create it on the computer side TCP server and then communicate 6 3 2 Network Model 6 3 3 Parameter configuration Set the module to STA mode and connect to the relevant WIFI hotspot router When the connection is successful the following info...

Page 18: ...ronic Technology Co Ltd E03 W05A User Manual Copyright 2012 2020 Chengdu Ebyte Electronic Technology Co Ltd 17 At this time also connect our computer to the same wifi as the module so that they are in a local area network ...

Page 19: ...A User Manual Copyright 2012 2020 Chengdu Ebyte Electronic Technology Co Ltd 18 On the computer create a server and monitor the relevant ports Set up the module and connect to the server When the connection is successful the receiving box will have the ...

Page 20: ...r we can perform data communication between the server and the client but here in order to achieve simple data transmission we need to make some settings to enter the transparent transmission mode so that we can avoid sending data every time The awkward operation of specifying the width After the client connects to the server perform the following operations to enter the transparent transmission ...

Page 21: ...bution network AIRKISS The E103 W05 module has a smart network configuration function The user can use the relevant mobile phone APP to configure the module to quickly connect to the network When the module is in STA mode click SmartC Open to enter the one key network configuration mode When the match is successful the module will access the same target WIFI as the mobile phone without entering ...

Page 22: ...he mobile phone needs to download the AIRKISS debugging APP officially provided by WeChat and the user can download and install it on the official website of Ebyte 6 3 2 Host computer configuration On the module side we click SmartC Open on the host computer to start the network configuration After the configuration is successful the module is connected to the same WIFI as the mobile phone and the...

Page 23: ...9 10 11 12 13 14 15 16 17 18 are used as ordinary GPIO among which E103 W05A Only GPIO15 and GPIO16 can be used When we want to control the output level of the relevant pin through the AT command or read the relevant level status we can use the following commands 6 4 1 AT CIOMODE Set the working mode of GPIO Instruction format AT CIOMODE pin mode pin pin label mode working mode 1 Output mode 0 inp...

Page 24: ...rmat AT CIOWRITE pin level pin pin label level working mode 1 High level 0 low level 6 4 3 AT CIOREAD Read GPIO level Instruction format pin pin label 6 4 5 Pin application example Use GPIO18 as output attribute and output low level AT CIOMODE 18 1 AT CIOWRITE 18 0 Use GPIO18 as an input attribute and read out the level AT CIOMODE 18 0 AT CIOREAD 18 The module reply is as follows ...

Page 25: ...rt baud rate The module supports the following baud rates 2000000 1500000 1250000 1000000 921600 406800 230400 115200 57600 38400 19200 9600 4800 2400 1800 1200 600 In the configuration of the host computer 115200 and 9600 setting buttons are provided If the user s setting requirements cannot be met the relevant AT commands can be used to set the baud rate After the baud rate is set it will take e...

Page 26: ...Chengdu Ebyte Electronic Technology Co Ltd E03 W05A User Manual Copyright 2012 2020 Chengdu Ebyte Electronic Technology Co Ltd 25 ...

Page 27: ...or the quality of the antenna itself is problematic 7 2 Module is easily damaged Please check the power supply to ensure that it is within the recommended power supply voltage If it exceeds the maximum value it will cause permanent damage to the module Please check the stability of the power supply the voltage should not fluctuate greatly and frequently Please ensure anti static operation during i...

Page 28: ...nually activate the transparent transmission with AT CIPSEND If the user wants to start the system For transparent transmission you need to make relevant settings in the following interface 7 3 2 AP The maximum number of connections connected to the server When establishing TCP Server and TCP Client pay attention to the option of opening and closing multiple connections When the module is used as ...

Page 29: ...sed mutually but users must make relevant settings according to the electrical characteristics of their own modules In addition due to different electrical characteristics E103 W05 series modules are not fully compatible with the AT commands of E103 W01 Therefore some AT commands applicable to E103 W01 are not fully applicable to E103 W05 For the detailed AT command set please refer to the manual ...

Page 30: ...37 Sn96 5 Ag3 Cu0 5 Preheat Temperature min Tsmin 100 150 Preheat temperature max Tsmax 150 200 Preheat Time Tsmin to Tsmax ts 60 120 sec 60 120 sec Average ramp up rate Tsmax to Tp 3 second max 3 second max Liquidous Temperature TL 183 217 Time tL Maintained Above TL 60 90 sec 30 90 sec Peak temperature Tp 220 235 230 250 Aveage ramp down rate Tp to Tsmax 6 second max 6 second max Time 25 to peak...

Page 31: ...oduct Size Package Interface Features Remark m mm E103 W05 W600 PCB 100 19 13 2 5mm SMD Serial port Standard product small size E103 W05A W600 PCB 130 24 7 14 4 11 2mm DIP Serial port DIP module without shield E103 W05B W600 IPEX 400 3dBi omnidirectional 17 16 2 5mm SMD Serial port External antenna long distance E103 W05C W600 PCB 150 24 16 2 5mm SMD Serial port Same package as E103 W01 ...

Page 32: ...prices Model No Type Frequency Gain Size Feeder Interface Feature Hz dBi mm cm TX2400 NP 5010 Flexible Antenna 2 4G 2 0 10x50 IPEX Flexible FPC antenna TX2400 JZ 3 Rubber antenna 2 4G 2 0 30 SMA J Ultra short straight omnidirectional antenna TX2400 JZ 5 Rubber antenna 2 4G 2 0 50 SMA J Ultra short straight omnidirectional antenna TX2400 JW 5 Rubber antenna 2 4G 2 0 50 SMA J Fixed bending omnidirec...

Page 33: ... 0 2020 6 18 Initial version Roy 1 1 2020 7 14 Format revision Li About us Technical support support cdebyte com Documents and RF Setting download link www ebyte com Thank you for using Ebyte products Please contact us with any questions or suggestions info cdebyte com Official hotline 028 61399028 Web www ebyte com Address B5 Mould Park 199 Xiqu Ave High tech District Sichuan China ...

Reviews: