2/2021 BA80122def05_EBI 12 Serie-EX
51
English
Français
EBI 12-T23x
Product line:
Blueline
Design:
axial, rigid probe with
3 mm diameter and
M5 thread
Measurement range:
EBI 12-T230 - 233 -55 °C ...+150 °C
EBI 12-T237
-40 °C ... +140 °C
Accuracy:
±0.5 °C (-55 °C ...-40 °C)
±0.2 °C (-40 °C ... 0 °C)
±0.1 °C (0 °C ... +150 °C)
EBI 12-T24x
Product line:
Redline
Design:
axial probe,
1.5 mm diameter
Measurement range: -200 °C ... +200 °C
Accuracy:
±1.5 °C (-200 °C ... -90 °C)
±0.5 °C (-90 °C ... -40 °C)
±0.2 °C (-40 °C ... 0 °C)
±0.1 °C (0 °C ... +120 °C)
±0.05 °C (+120 °C ... +140 °C)
±0.1 °C (+140 °C ... +150 °C)
±0.5 °C (+150 °C ... +200 °C)
EBI 12-T26x
Product line:
Blueline
Design:
axial probe with 6 mm
diameter and
M10 thread
Measurement range:
-55 °C ... +140 °C
Accuracy:
±0.8 °C (-55 °C ...-40 °C)
±0.3 °C (-40 °C ... +140 °C)
EBI 12-T285
Product line:
Redline
Design:
axial bendable probe
with 3 mm diameter
Measurement range: -40 °C ...+200 °C
Accuracy:
±0.3 °C (-40 °C ... 0 °C)
±0.2 °C (0 °C ... +150 °C)
±0.5 °C (+150 °C ... +200 °C)
EBI 12-T42x
Product line:
Redline
Design:
2 channel,
radial bendable probes,
1.5 mm diameter
Measurement range: -200 °C ... +400 °C
Accuracy:
±1.5 °C (-200 °C ... -90 °C)
±0.5 °C (-90 °C ... -40 °C)
±0.2 °C (-40 °C ... 0 °C)
±0.1 °C (0 °C ... +120 °C)
±0.05 °C (+120 °C ... +140 °C)
±0.1 °C (+140 °C ... +150 °C)
±0.5 °C (+150 °C ... +250 °C)
±0.8 °C (+250 °C ... +400 °C)
EBI 12-T23x
Gamme de produits
Blueline
Conception:
sonde axiale rigide avec
3 mm de diamètre et
Filetage M5
Plage de mesure:
EBI 12-T230 - 233 -55 °C ...+150 °C
EBI 12-T237
-40 °C ... +140 °C
Précision:
±0,5 °C (-55 °C ...-40 °C)
±0,2 °C (-40 °C ... 0 °C)
±0,1 °C (0 °C ... +150 °C)
EBI 12-T24x
Gamme de produits:
Redline
Conception:
sonde axiale,
1,5 mm de diamètre
plage de mesure:
-200 °C ... +200 °C
Précision:
±1,5 °C (-200 °C ... -90 °C)
±0,5 °C (-90 °C ... -40 °C)
±0,2 °C (-40 °C ... 0 °C)
±0,1 °C (0 °C ... +120 °C)
±0,05 °C (+120 °C ... +140 °C)
±0,1 °C (+140 °C ... +150 °C)
±0,5 °C (+150 °C ... +200 °C)
EBI 12-T26x
Gamme de produits:
Blueline
Conception:
sonde axiale avec 6 mm
diamètre et
Filetage M10
plage de mesure:
-55 °C ... +140 °C
Précision::
±0,8 °C (-55 °C ...-40 °C)
±0,3 °C (-40 °C ... +140 °C)
EBI 12-T285
Gamme de produits
Redline
Conception:
sonde pliable axiale de
3 mm de diamètre
plage de mesure:
-40 °C ...+200 °C
Précision:
±0,3 °C (-40 °C ... 0 °C)
±0,2 °C (0 °C ... +150 °C)
±0,5 °C (+150 °C ... +200 °C)
EBI 12-T42x
Gamme de produits
Redline
Conception:
2 canaux,
sondes flexibles
radiales,
1,5 mm de diamètre
plage de mesure
-200 °C ... +400 °C
Précision:
±1,5 °C (-200 °C ... -90 °C)
±0,5 °C (-90 °C ... -40 °C)
±0,2 °C (-40 °C ... 0 °C)
±0,1 °C (0 °C ... +120 °C)
±0,05 °C (+120 °C ... +140 °C)
±0,1 °C (+140 °C ... +150 °C)
±0,5 °C (+150 °C ... +250 °C)