Operating instructions
W3G800-GV01-91
`
II 2G Ex db eb ib IIB T3 Gb
IBExU14ATEX1123 X /03
`
Translation of the original operating instructions
54001-4-8670
All dimensions in mm.
This drawing shows how to install the guard grille with the article numbers specified in the product drawing. The necessary bolts, nuts and
washers are available from ebm-papst.
1
Guard grill for protection against accidental contact
2
Bolt M8x18 micro-encapsulated
3
Toothed lock washer
4
Contact washer (only necessary at one fixing point)
5
Nut M8
Attention! The guard grill may only be fastened to the four fastening points marked in the product drawing.
Use the fastening components available from ebm-papst for assembly.
At one mounting point, the contact washer (4) must also be inserted between the housing and the nut.
Tighten the bolts to a torque of 20 Nm ± 3 Nm.
If a guard grille other than that specified in the product drawing is installed, the operator must ensure proper installation according to the
ATEX directive.
In particular, it must be ensured that the necessary distance from rotating parts is observed and that static charge that arises is safely
dissipated. If you have any questions, please contact ebm-papst.
Item no. 54001-5-9970 · ENU · Change 272968 · Approved 2022-11-23 · Page 6 / 17