ebm-papst W2D250-GA02-10 Operating Instructions Manual Download Page 8

Operating instructions

W2D250-GA02-10

Translation of the original operating instructions

4.5 Connection diagram

Change of rotation direction by reversing two phases

1

Fan

Y

Star connection

2

red (+5 V)

L1

black

3

white (output)

L2

blue

4

black (0 V)

L3

brown

5

4 K7

TOP

2x gray

PE

green/yellow

Y

Star connection

L1

black

L2

blue

L3

brown

Item no. 15109-5-9970 · ENU · Change 84873 · Approved 2016-07-15 · Page 8 / 10

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com

Summary of Contents for W2D250-GA02-10

Page 1: ...rated maintained and otherwise used by suitably qualified trained and authorized technical staff Only authorized specialists are permitted to install the device to carry out a test run and to perform...

Page 2: ...e system machine wait until all parts have come to a standstill WARNING Rotating device Long hair and dangling items of clothing jewelry and the like can become entangled and be pulled into the device...

Page 3: ...ticular operating the device in the following ways is prohibited and could be hazardous Operating the device in an unbalanced state e g due to dirt deposits or ice formation Resonant operation operati...

Page 4: ...housing Tyco 2178474 2 3x plug pin Tyco 926886 1 1 1 L1 U1 black 1 2 L2 V1 blue 1 3 L3 W1 brown 2 Cable Raychem Spec 44 AWG24 3x crimped splices 3 Max clearance for screw 5 mm Item no 15109 5 9970 ENU...

Page 5: ...e ErP data is determined using a motor impeller combination in a standardized measurement setup 3 4 Technical description Weight 3 6 kg Fan size 250 mm Rotor surface Painted black Impeller material Sh...

Page 6: ...its that can be switched off with an all pole disconnection switch 4 2 1 Requirements Check whether the data on the nameplate match the connection data Before connecting the device make sure the power...

Page 7: ...r the version without thermal overload protector also install a suitable motor protection switch 4 4 Connection of the Hall IC The device has external leads Connect the cables according to your applic...

Page 8: ...Y Star connection 2 red 5 V L1 black 3 white output L2 blue 4 black 0 V L3 brown 5 4 K7 TOP 2x gray PE green yellow Y Star connection L1 black L2 blue L3 brown Item no 15109 5 9970 ENU Change 84873 A...

Page 9: ...ES Do not perform any repairs on your device Send the device to ebm papst for repair or replacement WARNING Live terminals and connections even with device switched off Electric shock Wait five minute...

Page 10: ...be performed or supervised by qualified personnel with the appropriate technical knowledge The product is to be disassembled into suitable components for disposal employing standard procedures for mot...

Reviews: