3.2 Nominal data

Motor

M2D068-DF

Phase

3~

3~

Nominal voltage / VAC

400

400

Wiring

Y

Y

Frequency / Hz

50

60

Method of obtaining
data

fa

fa

Valid for approval/
standard

CE

CE

Speed (rpm) / min

-1

2700

3000

Power consumption / W

112

180

Current draw / A

0.23

0.27

Max. back pressure / Pa

280

280

Min. ambient
temperature / °C

-25

-25

Max. ambient
temperature / °C

60

50

Starting current / A

0.78

0.75

ml = Max. load · me = Max. efficiency · fa = Free air

cs = Customer specification · ce = Customer equipment

Subject to change

3.3 Data according to Commission Regulation (EU) 327/
2011

Actual

Req. 2015

01 Overall efficiency η

es

/ %

28.1

28.1

02 Measurement category

A

03 Efficiency category

Static

04 Efficiency grade N

40

40

05 Variable speed drive

No

06 Year of manufacture

The year of manufacture is specified on the
product's rating label.

07 Manufacturer

ebm-papst Mulfingen GmbH & Co. KG
Amtsgericht (court of registration) Stuttgart
· HRA 590344
D-74673 Mulfingen

08 Type

W2D250-GA02-10

09 Power consumption P

e

/ kW

0.13

09 Air flow q

v

/ m³/h

1050

09 Pressure increase total p

sf

/

Pa

121

10 Speed (rpm) n / min

-1

2600

11 Specific ratio

*

1.00

12 Recycling/disposal

Information on recycling and disposal is
provided in the operating instructions.

13 Maintenance

Information on installation, operation and
maintenance is provided in the operating
instructions.

14 Additional components

Components used to calculate the energy
efficiency that are not apparent from the
measurement category are detailed in the
CE declaration.

*

Specific ratio = 1 + p

fs

/ 100 000 Pa

Data obtained at optimum efficiency level. The ErP data is determined using a motor-impeller

combination in a standardized measurement setup.

3.4 Technical description

Weight

3.6 kg

Fan size

250 mm

Rotor surface

Painted black

Impeller material

Sheet steel, painted black

Fan housing material

Sheet steel, galvanized

Guard grille material

Steel, phosphated and coated with black
plastic

Number of blades

5

Airflow direction

"A"

Direction of rotation

Clockwise, viewed toward rotor

Degree of protection

IP44; installation- and position-dependent

Insulation class

"B"

Moisture (F) /
Environmental (H)
protection class

F5

Installation position

Any

Condensation
drainage holes

None

Mode

S1

Motor bearing

Ball bearing

Touch current
according to IEC
60990 (measuring
circuit Fig. 4, TN
system)

< 0.75 mA

with cable

Lateral

Protection class

I (if protective earth is connected by
customer to the housing's connection point)

Conformity with
standards

EN 60335-1, motor does not have
factory-installed overheating protection

With regard to cyclic speed loads, note that the rotating parts of
the device are designed for a maximum of one million load
cycles. If you have special questions, consult ebm-papst for
support.

3.5 Mounting data

For screw clearance, see Chapter 3.1 Product drawing

;

Secure the screws against unintentional loosening (e.g. use self-
locking screws).

Strength class of
screws

8.8

Any further mounting data required can be taken from the product drawing.

3.6 Transport and storage conditions

;

Use the device in accordance with its degree of protection.

Max. permitted
ambient temp. for
motor (transport/
storage)

+ 80 °C

Min. permitted
ambient temp. for
motor (transport/
storage)

- 40 °C

Item no. 15109-5-9970 · ENU · Change 84873 · Approved 2016-07-15 · Page 5 / 10

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com

Summary of Contents for W2D250-GA02-10

Page 1: ...rated maintained and otherwise used by suitably qualified trained and authorized technical staff Only authorized specialists are permitted to install the device to carry out a test run and to perform...

Page 2: ...e system machine wait until all parts have come to a standstill WARNING Rotating device Long hair and dangling items of clothing jewelry and the like can become entangled and be pulled into the device...

Page 3: ...ticular operating the device in the following ways is prohibited and could be hazardous Operating the device in an unbalanced state e g due to dirt deposits or ice formation Resonant operation operati...

Page 4: ...housing Tyco 2178474 2 3x plug pin Tyco 926886 1 1 1 L1 U1 black 1 2 L2 V1 blue 1 3 L3 W1 brown 2 Cable Raychem Spec 44 AWG24 3x crimped splices 3 Max clearance for screw 5 mm Item no 15109 5 9970 ENU...

Page 5: ...e ErP data is determined using a motor impeller combination in a standardized measurement setup 3 4 Technical description Weight 3 6 kg Fan size 250 mm Rotor surface Painted black Impeller material Sh...

Page 6: ...its that can be switched off with an all pole disconnection switch 4 2 1 Requirements Check whether the data on the nameplate match the connection data Before connecting the device make sure the power...

Page 7: ...r the version without thermal overload protector also install a suitable motor protection switch 4 4 Connection of the Hall IC The device has external leads Connect the cables according to your applic...

Page 8: ...Y Star connection 2 red 5 V L1 black 3 white output L2 blue 4 black 0 V L3 brown 5 4 K7 TOP 2x gray PE green yellow Y Star connection L1 black L2 blue L3 brown Item no 15109 5 9970 ENU Change 84873 A...

Page 9: ...ES Do not perform any repairs on your device Send the device to ebm papst for repair or replacement WARNING Live terminals and connections even with device switched off Electric shock Wait five minute...

Page 10: ...be performed or supervised by qualified personnel with the appropriate technical knowledge The product is to be disassembled into suitable components for disposal employing standard procedures for mot...