4.4 Connection diagram

Change of rotation direction by reversing two phases

Three-phase motor

Δ

Delta connection

Y

Star connection

L1

= U1 = black

L2

= V1 = blue

L3

= W1 = brown

U2

green

V2

white

W2

yellow

Item no. 10143-5-9970 · ENU · Change 89437 · Approved 2016-05-20 · Page 8 / 10

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com

Summary of Contents for W2D200-CI18-01

Page 1: ...only be transported unpacked installed operated maintained and otherwise used by suitably qualified trained and authorized technical staff Only authorized specialists are permitted to install the devi...

Page 2: ...fore working on the system machine wait until all parts have come to a standstill WARNING Rotating device Long hair and dangling items of clothing jewelry and the like can become entangled and be pull...

Page 3: ...ta Operating the device with all protective devices Following the operating instructions Improper use In particular operating the device in the following ways is prohibited and could be hazardous Oper...

Page 4: ...ons in mm 1 Cable PVC 7x crimped splices 2 Direction of air flow A 3 Direction of rotation counterclockwise viewed toward rotor Item no 10143 5 9970 ENU Change 89437 Approved 2016 05 20 Page 4 10 ebm...

Page 5: ...CE Approval EAC With regard to cyclic speed loads note that the rotating parts of the device are designed for a maximum of one million load cycles If you have special questions consult ebm papst for...

Page 6: ...N 60335 for the protective earth connection circuit must be verified in the end application Depending on the circumstances of installation it may be necessary to connect an additional protective earth...

Page 7: ...any automatic overheating protection The device can become hot and catch fire For the version without thermal overload protector also install a suitable motor protection switch Item no 10143 5 9970 E...

Page 8: ...eversing two phases Three phase motor Delta connection Y Star connection L1 U1 black L2 V1 blue L3 W1 brown U2 green V2 white W2 yellow Item no 10143 5 9970 ENU Change 89437 Approved 2016 05 20 Page 8...

Page 9: ...or restarts automatically when operating voltage is applied e g after a power failure Risk of injury Keep out of the device s danger zone When working on the device switch off the line voltage and ens...

Page 10: ...to be heeded 5 3 2 Disassembly Disassembly of the product must be performed or supervised by qualified personnel with the appropriate technical knowledge The product is to be disassembled into suitab...