Fans installed upright

Fig. 3: Cable routing for fans installed upright.
The cables must always be routed downward.

Fig. 4: Cable routing for fans installed upright. The cables must always
be routed downward.

4.3.2 Motor protection

CAUTION
Voltage

The device is a built-in component and has no disconnecting
switch.
→ Connect the device to a suitable tripping unit.
→ Only connect the device to circuits that can be switched

off with an all-pole disconnection switch.

→ When working on the device, secure the system/

machine in which the device is installed so as to prevent it
from being switched back on.

NOTE
Lack of motor protection

Without motor protection, the motor can overheat and suffer
damage.
→ Connect the thermal overload protector installed in the

winding.

The motors are equipped with thermal overload protectors to protect the
devices.
Check to make sure that the thermal overload protector is correctly
connected before each operation.

Failure to connect the thermal overload protector correctly will
invalidate your warranty claim.

Item no. 12939-5-9970 · ENU · Change 84370 · Approved 2016-06-16 · Page 7 / 10

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com

Summary of Contents for W2D170-AA04-52

Page 1: ...nly be transported unpacked installed operated maintained and otherwise used by suitably qualified trained and authorized technical staff Only authorized specialists are permitted to install the devic...

Page 2: ...e rotor or the impeller Secure the device against accidental contact Before working on the system machine wait until all parts have come to a standstill WARNING Rotating device Long hair and dangling...

Page 3: ...perating instructions Improper use In particular operating the device in the following ways is prohibited and could be hazardous Operating the device in an unbalanced state e g due to dirt deposits or...

Page 4: ...1 Product drawing All dimensions in mm 1 Direction of air flow A 2 Cable AWG20 9x crimped splices Item no 12939 5 9970 ENU Change 84370 Approved 2016 06 16 Page 4 10 ebm papst Mulfingen GmbH Co KG Bac...

Page 5: ...ta For screw clearance see Chapter 3 1 Product drawing Secure the screws against unintentional loosening e g use self locking screws Strength class of screws 8 8 Any further mounting data required can...

Page 6: ...resistance according to EN 60335 Compliance with the impedance specifications according to EN 60335 for the protective earth connection circuit must be verified in the end application Depending on th...

Page 7: ...device secure the system machine in which the device is installed so as to prevent it from being switched back on NOTE Lack of motor protection Without motor protection the motor can overheat and suf...

Page 8: ...ion Delta connection L1 U1 black 2 L2 V1 black 1 L3 W1 black 3 V2 black 4 U2 black 5 W2 black 6 TOP thermal overload protector 2x yellow Item no 12939 5 9970 ENU Change 84370 Approved 2016 06 16 Page...

Page 9: ...LFUNCTIONS POSSIBLE CAUSES AND REMEDIES Do not perform any repairs on your device Send the device to ebm papst for repair or replacement WARNING Live terminals and connections even with device switche...

Page 10: ...regard to the disposal of products or waste occurring in the various phases of the life cycle The corresponding disposal standards are also to be heeded 5 3 2 Disassembly Disassembly of the product mu...

Reviews: