2. PROPER USE

The device is exclusively designed as a built-in device for moving air
according to its technical data.
Any other or secondary use is deemed improper and constitutes a
misuse of the device.
Installations on the customer's side must meet the mechanical, thermal
and service life-related stresses that can occur.

Proper use also includes:

Moving air with a density of 1.2 kg/m³.

Using the device in accordance with the permitted ambient
temperature, see chapter 3.5 Transport and storage conditions and
chapter 3.2 Nominal data.

Operating the device with all protective features in place.

Minding the operating instructions.

Improper use

Using the device in the following ways is particularly prohibited and
may cause hazards:

Operating the device with an imbalance, e.g. caused by dirt deposits
or icing.

Moving air that contains abrasive particles.

Moving highly corrosive air, e.g. salt spray mist. Exceptions are
devices that are intended for salt spray mist and protected accordingly.

Moving air that contains dust pollution, e.g. suctioning off saw dust.

Operating the device close to flammable materials or components.

Operating the device in an explosive atmosphere.

Using the device as a safety component or for taking on safety-
related functions.

Operation with completely or partially disassembled or modified
protective features.

In addition, all application options that are not listed under proper use.

Item no.: 50581-5-9970 · Revision: 70943 · Print-out: 2012-02-24 · Y. Uhlmann (VM-TDO) · Page 3 / 9

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 7938 81-0 · Fax +49 7938 81-110 · [email protected] · www.ebmpapst.com

Summary of Contents for W1G250-CH67-52

Page 1: ...st personnel are permitted to transport unpack assemble operate or maintain the device or to use it in any other manner 1 3 Basic safety rules 1 1 3 Basic safety rules Any safety hazards stemming from...

Page 2: ...come to a standstill WARNING Rotating device Long hair loose items of clothing and jewellery could become entangled and pulled into the device You could be injured Do not wear any loose clothing or je...

Page 3: ...lowing ways is particularly prohibited and may cause hazards Operating the device with an imbalance e g caused by dirt deposits or icing Moving air that contains abrasive particles Moving highly corro...

Page 4: ...ucts All measures have the unit mm 1 Direction of air flow V 2 Connecting cable AWG 20 4 x brass lead tips crimped Item no 50581 5 9970 Revision 70943 Print out 2012 02 24 Y Uhlmann VM TDO Page 4 9 eb...

Page 5: ...cal features Control input 0 10 VDC PWM Tach output Motor current limit Soft start Motor protection Reverse polarity and locked rotor protection Cable exit Lateral Product conforming to standard EN 60...

Page 6: ...dry environment Operate the device with a safely isolated power pack 4 2 1 Prerequisites Check whether the data on the type plate agree with the connection data Before connecting the device ensure th...

Page 7: ...C residual ripple 3 5 1 2 0 10 VDC yellow Control input Re 100 K 1 3 DUE white Speed monitoring output 3 pulses per rotation Isink max 10 mA 1 4 GND blue Reference mass Item no 50581 5 9970 Revision 7...

Page 8: ...n with a unit that is shut off Electric shock Wait five minutes after disconnecting the voltage at all poles before opening the device CAUTION If control voltage is applied or a speed setpoint is stor...

Page 9: ...ich measure Check the protective casing against accidental contact for damage and to ensure that it is intact Visual inspection At least every 6 months Repair or replacement of the device Check the de...