background image

Operating instructions

W1G208-BA73-12

GOOGLE USA

Translation of the original operating instructions

3.2 Nominal data

Motor

M1G074-BF

Nominal voltage / VDC

48

Nominal voltage
range / VDC

36 .. 57

Type of data definition

fa

Speed / min

-1

3500

Power input / W

96

Current draw / A

2.2

Max. back pressure / Pa

230

Min. ambient temperature
/ °C

-25

Max. ambient
temperature
/ °C

72

ml = Max. load · me = Max. efficiency · fa = Running at free air

cs = Customer specs · cu = Customer unit

Subject to alterations

3.3 Technical features

Mass

2.28 kg

Size

208 mm

Surface of rotor

Coated in black

Material of impeller

Plastic PA66, fibreglass-reinforced

Material of wall ring

Die-cast aluminium, coated in black

Number of blades

5

Direction of air flow

"V"

Direction of rotation

Counter-clockwise, seen on rotor

Type of protection

IP 20

Insulation class

"B"

Humidity class

F0

Mounting position

Any

Condensate discharge
holes

None

Operation mode

S1

Motor bearing

Ball bearing

Technical features

- Tach output
- Motor current limit
- Soft start
- Control input 0-10 VDC / PWM

Electrical leads

With plug

Motor protection

Reverse polarity and locked-rotor
protection

Cable exit

Lateral

Product conforming
to standard

EN 60950-1

Approval

UL 1004-1; CSA C22.2 Nr.77

For cyclic speed loads, note that the rotating parts of the device
are designed for maximum one million load cycles. If you have
specific questions, contact ebm-papst for support.

3.4 Mounting data

For depth of screw, see chapter 3.1 Product drawing

;

Secure the mounting screws against accidentally coming loose (e.g.
by using self-locking screws).

Strength class for
mounting screws

8.8

You can obtain additional mounting data from the product drawing if
necessary.

3.5 Transport and storage conditions

;

Use the device in accordance with its protection type.

Max. permissible
ambient motor temp.
(transp./ storage)

+ 80 °C

Min. permissible
ambient motor temp.
(transp./storage)

- 40 °C

3.6 Electromagnetic compatibility

EMC interference
immunity

Acc. to EN 61000-6-2 (industrial
environment)

EMC interference
emission

Acc. to EN 55022 (Class B)

Item no. 51090-5-9970 · ENG · Revision 83494 · Release 2014-09-25 · Page 5 / 9

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com

Summary of Contents for W1G208-BA73-12

Page 1: ...ical staff Only authorised specialists are permitted to install the device to carry out a test run and to perform work on the electrical installation 1 3 Basic safety rules 1 1 3 Basic safety rules An...

Page 2: ...it until all parts have come to a standstill WARNING Rotating device Long hair loose items of clothing and jewellery could become entangled and pulled into the device You could be injured Do not wear...

Page 3: ...in the following ways is particularly prohibited and may cause hazards Operating the device with an imbalance e g caused by dirt deposits or icing Moving air that contains abrasive particles Moving h...

Page 4: ...of air flow V 2 Connector housing Molex 39 01 2040 connection line AWG20 with 4x connector socket Molex 39 00 0059 2 1 red 2 2 Control input yellow 2 3 blue 2 4 S white Item no 51090 5 9970 ENG Revisi...

Page 5: ...lectrical leads With plug Motor protection Reverse polarity and locked rotor protection Cable exit Lateral Product conforming to standard EN 60950 1 Approval UL 1004 1 CSA C22 2 Nr 77 For cyclic speed...

Page 6: ...y environment Operate the device with a safely isolated power pack 4 2 1 Prerequisites Check whether the data on the type plate agree with the connection data Before connecting the device ensure that...

Page 7: ...supply 48 VDC residual ripple 3 5 1 2 0 10 VDC yellow Control input Re 100 K 1 3 Tach white Speed monitoring output 3 pulses per rotation Isink max 10 mA 1 4 GND blue Reference mass Item no 51090 5 9...

Page 8: ...he supply voltage 5 MAINTENANCE MALFUNCTIONS POSSIBLE CAUSES AND REMEDIES Do not perform any repairs on your device Return the device to ebm papst for repair or replacement WARNING Terminals and conne...

Page 9: ...ses or solvents Do not use any pointed or sharp edged objects to clean 5 2 Safety test What has to be tested How to test Frequency Which measure Check the protective casing against accidental contact...