3.2 Nominal data

Motor

M1G074-BF

Nominal voltage / VDC

48

Nominal voltage
range / VDC

36 .. 57

Frequency / Hz

-

Method of obtaining
data

fa

Speed (rpm) / min

-1

2950

Power consumption / W

55

Current draw / A

1.3

Max. back pressure / Pa

120

Min. ambient
temperature / °C

-25

Max. ambient
temperature / °C

60

ml = Max. load · me = Max. efficiency · fa = Free air

cs = Customer specification · ce = Customer equipment

Subject to change

3.3 Technical description

Weight

2.1 kg

Size

200 mm

Motor size

74

Rotor surface

Painted black

Blade material

Sheet steel, painted black

Fan housing material

Die-cast aluminum

Number of blades

9

Airflow direction

V

Direction of rotation

Counterclockwise, viewed toward rotor

Degree of protection

IP42

Insulation class

"B"

Moisture (F) /
Environmental (H)
protection class

H0 - dry environment

Installation position

Any

Condensation
drainage holes

None

Mode

S1

Motor bearing

Ball bearing

Technical features

- Tach output
- Motor current limitation
- Soft start
- Control input 0-10 VDC / PWM

Electrical hookup

Plug; Via terminal strip

Motor protection

Reverse polarity and locked-rotor
protection

Protection class

I (with customer connection of protective
earth)

Conformity with
standards

EN 60950-1

Approval

CSA C22.2 No. 77; CCC; EAC; UL
1004-1

With regard to cyclic speed loads, note that the rotating parts of
the device are designed for a maximum of one million load
cycles. If you have special questions, consult ebm-papst for
support.

;

Use the device in accordance with its degree of protection.

Information on surface quality

The surfaces of the products conform to the generally applicable industrial
standard. The surface quality may change during the production period.
This has no effect on strength, dimensional stability and dimensional
accuracy.
The color pigments in the paints used perceptibly react to UV light over
the course of time. This does not however in any way affect the
technical properties of the products. The product is to be protected against
UV radiation to prevent the formation of patches and fading. Changes in
color are not a reason for complaint and are not covered by the warranty.

3.4 Mounting data

;

Secure the screws against unintentional loosening (e.g. use self-
locking screws).

For screw clearance, see Chapter 3.1 Product drawing

Strength class of
screws

8.8

Any further mounting data required can be taken from the product
drawing or Section Chapter 4.1 Mechanical connection.

3.5 Transport and storage conditions

Max. permitted
ambient temp. for
motor (transport/
storage)

+ 80 °C

Min. permitted
ambient temp. for
motor (transport/
storage)

- 40 °C

3.6 Electromagnetic compatibility

EMC immunity to
interference

According to EN 61000-6-2 (industrial
environment)

EMC interference
emission

According to EN 55022 (Class B)

Item no. 50290-5-9970 · ENU · Change 202174 · Approved 2019-01-04 · Page 5 / 9

·

·

·

·

·

·

Summary of Contents for W1G200-HH01-52

Page 1: ...zed technical staff Only authorized specialists are permitted to install the device to carry out a test run and to perform work on the electrical installation 1 3 Basic safety rules 1 1 3 Basic safety...

Page 2: ...t 1 7 Mechanical movement DANGER Rotating device Risk of injury to body parts coming into contact with the rotor or the impeller Secure the device against accidental contact Before working on the syst...

Page 3: ...r operating the device in the following ways is prohibited and could be hazardous Operating the device in an unbalanced state e g due to dirt deposits or ice formation Resonant operation operation wit...

Page 4: ...instructions 3 TECHNICAL DATA 3 1 Product drawing All dimensions in mm 1 Connection terminal strip with 5 terminals 1 1 UN 48 VDC red 1 2 GND blue 1 3 DUE white 1 4 0 10 VDC yellow 2 Direction of air...

Page 5: ...ads note that the rotating parts of the device are designed for a maximum of one million load cycles If you have special questions consult ebm papst for support Use the device in accordance with its d...

Page 6: ...t and has no disconnecting switch Only connect the fan to circuits that can be switched off with an all pole disconnection switch When working on the fan secure the system machine in which the fan is...

Page 7: ...reliminary No Conn Designation Color Function assignment 1 1 Un 48 VDC red Power supply 48 VDC maximum ripple 3 5 1 2 0 10 VDC yellow Control input Re 100k 1 3 Tach white Tach output 3 pulses per revo...

Page 8: ...e device for maintenance Switch off the device via the control input Do not switch the motor e g in cyclic operation on and off via power supply Disconnect the device from the power supply 5 MAINTENAN...

Page 9: ...fic legal requirements NOTE Country specific legal requirements Always observe the applicable country specific legal regulations with regard to the disposal of products or waste occurring in the vario...

Reviews: